Determination of porphyrins in bile using high performance liquid chromatography and some clinical applications.

نویسندگان

  • G J Beukeveld
  • L Meerman
  • J R Huizenga
  • E E Venekamp-Hoolsema
  • C H Gips
  • B G Wolthers
چکیده

A simple and fast HPLC method for the determination of porphyrins in bile without extraction is described. Porphyrins were determined in bile from control subjects and from patients after orthotopic liver transplantation, including three patients with erythropoietic protoporphyria. It was found that: 1) coproporphyrin I is the predominant porphyrin in bile of controls, accompanied by some coproporphyrin III and protoporphyrin, whereas protoporphyrin mostly but not always is the predominant porphyrin in the bile of erythropoietic protoporphyria patients. In two of the three erythropoietic protoporphyria patients, the bile contained a hundred times more protoporphyrin than that of non-porphyric orthotopic liver transplantation patients. The third erythropoietic protoporphyria patient remained cholestatic and was unable to excrete sufficient amounts of protoporphyrin. 2) All investigated bile samples contained no secondary porphyrins derived from protoporphyrin, i.e. no deutero-, pempto-, or mesoporphyrin. Even when extracts of bile and serum were concentrated fifty to a hundred times, no traces of deutero-, pempto- and mesoporphyrin were detected. This complete absence of secondary porphyrins suggests that an enterohepatic circulation of dicarboxylic porphyrins from the distal gastrointestinal tract does not exist. 3) The HPLC chromatograms contain peaks from unknown compounds. No correlation between porphyrins and these compounds was found. Porphyrin profiles were followed in the bile of some orthotopic liver transplantation patients. Three episodes are recognizable. During the first three days after orthotopic liver transplantation there is a very high coproporphyrin excretion. There is then a lag of one to three weeks, in which no or very low porphyrin concentrations are detectable, followed by the restoration of normal biliary porphyrin patterns.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of some B Vitamins in Sour Cherry Juice Using Dispersive Liquid-liquid Microextraction Followed by High-performance Liquid Chromatography

Dispersive liquid-liquid microextraction method (DLLME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was used to determine thiamine (B1), nicotinamide (B3) and pyridoxine (B6) in sour cherry juice. This method was rapid, simple and sensitive. Separation was accomplished using a C18 column. The optimum chromatographic conditions were found to be: mobile ph...

متن کامل

Simultaneous Determination of Four Preservatives in Foodstuffs by High Performance Liquid Chromatography

Background and objectives:  High concentration of preservatives in food may result in gastrointestinal disturbances whereby some patients suffering from asthma, rhinitis, or urticaria. The aim of this study is the introduction and optimization a new method for simultaneous determination of four preservatives (SB, PS, MP, PP) in foodstuff by high performance liquid chromatography. Materi...

متن کامل

Determination of some B Vitamins in Sour Cherry Juice Using Dispersive Liquid-liquid Microextraction Followed by High-performance Liquid Chromatography

Dispersive liquid-liquid microextraction method (DLLME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was used to determine thiamine (B1), nicotinamide (B3) and pyridoxine (B6) in sour cherry juice. This method was rapid, simple and sensitive. Separation was accomplished using a C18 column. The optimum chromatographic conditions were found to be: mobile ph...

متن کامل

Determination of porphyrins and biliverdin in bile and excreta of birds by a single liquid chromatography-ultraviolet detection analysis.

Methods developed for porphyrin analysis have low recoveries and/or poor precision for the less polar protoporphyrin IX. We describe a simple method of analysis of porphyrins and biliverdin in bile and excreta of birds based on extraction with HCl 3N: acetonitrile and HPLC/UV analyses. Recoveries were good for protoporphyrin IX and other porphyrins (>79%). Applications of this method showed tha...

متن کامل

Trace Determination of Duloxetine in Human Plasma by a Novel Ionic Liquid-Based Ultrasound-Assisted In Situ Solvent Formation Microextraction and High-Performance Liquid Chromatography

For the first time, a novel and efficient ionic liquid-based ultrasound-assisted in-situ solvent formation microextraction (IL-UA-ISFME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) has been successfully developed for the determination of duloxetine (DLX) in human plasma. Herein, an environmentally-friendly hydrophobic ionic liquid (1-butyl-3-methylimidaz...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies

دوره 32 3  شماره 

صفحات  -

تاریخ انتشار 1994