The influence of left ventricular ejection fraction on the effectiveness of cardiac resynchronization therapy: MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy).
نویسندگان
چکیده
OBJECTIVES The aim of this study was to evaluate the relationship between left ventricular (LV) ejection fraction and clinical outcome to cardiac resynchronization therapy (CRT) in mild heart failure patients enrolled in MADIT-CRT [corrected]. BACKGROUND Left ventricular ejection fraction (LVEF) is a surrogate marker of heart failure (HF) status and associated risk. Data on the effectiveness of cardiac resynchronization therapy with defibrillator (CRT-D) in patients with mild HF and better LVEF are limited. METHODS In the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy) study, the echocardiography core laboratory assessed baseline LVEF independent of the enrolling centers and identified a range of LVEFs, including those >30% (i.e., beyond the eligibility criteria). Echocardiographic response with CRT, defined as percent change in left ventricular end-diastolic volume (LVEDV), was analyzed in 3 prespecified LVEF groups: >30%, 26% to 30%, and ≤25%. The primary endpoint was HF or death. Secondary endpoint included all-cause mortality. RESULTS LVEF was evaluated in 1,809 study patients. There were 696 (38%) patients with LVEF >30% (in the range of 30.1% to 45.3%); 914 patients (50.5%) with LVEF 26% to 30%; and 199 patients with LVEF ≤25% (11%). The mean reduction in LVEDV with CRT-D therapy at the 1-year follow-up was directly related to increasing LVEF (LVEF >30%: 22.3%; LVEF 26% to 30%: 20.1%; and LVEF ≤25%: 18.7% reduction, respectively [p = 0.001]). CRT-D treatment similarly reduced the risk of HF/death in patients with LVEF >30% (hazard ratio [HR]: = 0.56 [95% confidence interval (CI): 0.39 to 0.82], p = 0.003), LVEF 26% to 30% (HR: 0.67: [95% CI: 0.50 to 0.90], p = 0.007), and LVEF ≤25% (HR: 0.57 [95% CI: 0.35 to 0.95], p = 0.03; all p values for LVEF-by-treatment interactions >0.1). CONCLUSIONS In MADIT-CRT, the clinical benefit of CRT was evident regardless of baseline LVEF, including those with LVEF >30%, whereas the echocardiographic response was increased with increasing LVEF, indicating that CRT might benefit patients with better LVEF. (Multicenter Automatic Defibrillator Implantation With Cardiac Resynchronization Therapy [MADIT-CRT]; NCT00180271).
منابع مشابه
The Influence of Left Ventricular Ejection Fraction on the Effectiveness of Cardiac Resynchronization Therapy
Methods In the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy) study, the echocardiography core laboratory assessed baseline LVEF independent of the enrolling centers and identified a range of LVEFs, including those 30% (i.e., beyond the eligibility criteria). Echocardiographic response with CRT, defined as percent change in left ventric...
متن کاملEffectiveness of Cardiac Resynchronization Therapy by QRS Morphology in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT).
BACKGROUND This study aimed to determine whether QRS morphology identifies patients who benefit from cardiac resynchronization therapy with a defibrillator (CRT-D) and whether it influences the risk of primary and secondary end points in patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT) trial. METHODS AND RESULTS Base...
متن کاملHeart Failure Effect of Cardiac Resynchronization Therapy on Reverse Remodeling and Relation to Outcome Multicenter Automatic Defibrillator Implantation Trial: Cardiac Resynchronization Therapy
Background—Cardiac resynchronization therapy (CRT) plus implantation of an implantable cardioverter defibrillator (ICD) reduced the risk of death or heart failure event in patients with mildly symptomatic heart failure, left ventricular dysfunction, and wide QRS complex compared with an ICD only. We assessed echocardiographic changes in patients enrolled in the MADIT-CRT trial (Multicenter Auto...
متن کاملCardiac resynchronization therapy reduces the risk of cardiac events in patients with diabetes enrolled in the multicenter automatic defibrillator implantation trial with cardiac resynchronization therapy (MADIT-CRT).
BACKGROUND Data are limited regarding whether the presence of diabetes mellitus (DM) influences the benefit of cardiac resynchronization with defibrillator therapy (CRT-D) in heart failure (HF) patients. METHODS AND RESULTS The effect of CRT-D was evaluated in 1817 patients who were enrolled in the Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy (...
متن کاملEffect of cardiac resynchronization therapy on reverse remodeling and relation to outcome: multicenter automatic defibrillator implantation trial: cardiac resynchronization therapy.
BACKGROUND Cardiac resynchronization therapy (CRT) plus implantation of an implantable cardioverter defibrillator (ICD) reduced the risk of death or heart failure event in patients with mildly symptomatic heart failure, left ventricular dysfunction, and wide QRS complex compared with an ICD only. We assessed echocardiographic changes in patients enrolled in the MADIT-CRT trial (Multicenter Auto...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 61 9 شماره
صفحات -
تاریخ انتشار 2013