Algorithm for Quantifying Frontal EMG Responsiveness for Sedation Monitoring.

نویسندگان

  • Timo Petteri Lapinlampi
  • Hanna Elina Viertiö-Oja
  • Matti Helin
  • Kimmo Henrik Uutela
  • Mika Olli Kristian Särkelä
  • Anne Vakkuri
  • Gordon Bryan Young
  • Timothy Simon Walsh
چکیده

INTRODUCTION To study stimulation-related facial electromyographic (FEMG) activity in intensive care unit (ICU) patients, develop an algorithm for quantifying the FEMG activity, and to optimize the algorithm for monitoring the sedation state of ICU patients. METHODS First, the characteristics of FEMG response patterns related to vocal stimulation of 17 ICU patients were studied. Second, we collected continuous FEMG data from 30 ICU patients. Based on these data, we developed the Responsiveness Index (RI) algorithm that quantifies FEMG responses. Third, we compared the RI values with clinical sedation level assessments and adjusted algorithm parameters for best performance. RESULTS In patients who produced a clinically observed response to the vocal stimulus, the poststimulus FEMG power was 0.33 µV higher than the prestimulus power. In nonresponding patients, there was no difference. The sensitivity and specificity of the developed RI for detecting deep sedation in the subgroup with low probability of encephalopathy were 0.90 and 0.79, respectively. CONCLUSION Consistent FEMG patterns were found related to standard stimulation of ICU patients. A simple and robust algorithm was developed and good correlation with clinical sedation scores achieved in the development data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A randomized controlled proof-of-concept trial of early sedation management using Responsiveness Index monitoring in mechanically ventilated critically ill patients

INTRODUCTION Deep sedation is associated with adverse patient outcomes. We recently described a novel sedation-monitoring technology, the Responsiveness Index (RI), which quantifies patient arousal using processed frontal facial EMG data. We explored the potential effectiveness and safety of continuous RI monitoring during early intensive care unit (ICU) care as a nurse decision-support tool. ...

متن کامل

Extended Monitoring of the Sedated Patient: Bispectral Index, Narcotrend® and Automated Responsiveness Monitor

It has been demonstrated that a processed EEG derivative may reflect the patient’s level of consciousness during endoscopic sedation. However, to date a clinical benefit of EEG monitoring with respect to relevant safety parameters in routine gastrointestinal endoscopy has not been demonstrated. During long-lasting procedures (e.g. ERCP, ESD) a propofol-sparing effect has been shown, but a benef...

متن کامل

Automated responsiveness test and bispectral index monitoring during propofol and propofol/N2O sedation.

BACKGROUND Sedation practice, especially when non-anaesthesia personnel are involved, requires efficient anaesthetic depth monitoring. Therefore, we used prediction probability (PK) to evaluate the performance of the bispectral index (BIS) of the EEG and automated responsiveness test (ART) to predict sedation depth and loss of subject's responsiveness during propofol sedation, with and without ...

متن کامل

Evaluation of the SEDline to improve the safety and efficiency of conscious sedation.

Brain function monitors have improved safety and efficiency in general anesthesia; however, they have not been adequately tested for guiding conscious sedation for periodontal surgical procedures. This study evaluated the patient state index (PSI) obtained from the SEDline monitor (Sedline Inc., San Diego, CA) to determine its capacity to improve the safety and efficiency of intravenous conscio...

متن کامل

Extended monitoring of the sedated patient: bispectral index, Narcotrend and automated responsiveness monitor.

It has been demonstrated that a processed EEG derivative may reflect the patient's level of consciousness during endoscopic sedation. However, to date a clinical benefit of EEG monitoring with respect to relevant safety parameters in routine gastrointestinal endoscopy has not been demonstrated. During long-lasting procedures (e.g. ERCP, ESD) a propofol-sparing effect has been shown, but a benef...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Canadian journal of neurological sciences. Le journal canadien des sciences neurologiques

دوره 41 5  شماره 

صفحات  -

تاریخ انتشار 2014