Enhanced State Estimation by Advanced Substation Monitoring

نویسنده

  • Mladen Kezunovic
چکیده

This is a project report from the Power Systems Engineering Research Center (PSERC). PSERC is a multi-university Center conducting research on challenges facing a restructuring electric power industry and educating the next generation of power engineers. Notice Concerning Copyright Material PSERC members are given permission to copy without fee all or part of this publication for internal use if appropriate attribution is given to this document as the source material. This report is available for downloading from the PSERC website. Executive Summary Power system substations are becoming equipped with intelligent electronic devices (IEDs) that are primarily used for protection and relaying functions as well as for power quality monitoring. The advanced communication and computational capabilities provided by these devices can be exploited to improve energy management system (EMS) applications. This project is concerned about one such application: the monitoring of power systems during normal operating conditions. Conventional monitoring involves scanning the measurements from various substations in the system and estimating the system state using a state estimator at the EMS control center. While state estimators can detect and identify most types of analog measurement errors, they are still vulnerable to errors in system topology. These errors show up when the assumed status of circuit breakers and switches does not coincide with their true status. This project investigates solutions to the detection, identification and elimination of such errors via the help of substation IEDs. One of the reasons why certain topological errors go undetected is that some measurements at the substation level cannot be used by the state estimator. This is because the overall system model does not include the detailed representation of substation configurations. In this project, these redundant substation-level measurements are integrated into the state estimator to improve topology error identification, error rejection and statistical robustness features. Furthermore, other error sources that are not topological, such as errors due to phase imbalances, are analyzed to determine their influence on the state estimation results. This project's results suggest that processing measurements at the substation level before sending them to the control center can improve state estimator performance. In addition, availability of detailed substation measurements can facilitate topology error identification by the state estimator executed at the control-center level. These benefits are demonstrated under various operating scenarios using prototype software developed as part of the project.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Special Issue on Real-Time Fault Diagnosis and Fault-Tolerant Control, IEEE Transaction on Industrial Electronics

With ongoing efforts to make the power grid smarter, there is a large emphasis on the automation and data analytics. Substation automation is a key enabling technology for online monitoring, diagnosis and prediction for the health condition of the substation assets. Circuit breakers (CB) are one of the most vital components in a substation for tripping action required during the fault occurrenc...

متن کامل

An Effective Attack-Resilient Kalman Filter-Based Approach for Dynamic State Estimation of Synchronous Machine

Kalman filtering has been widely considered for dynamic state estimation in smart grids. Despite its unique merits, the Kalman Filter (KF)-based dynamic state estimation can be undesirably influenced by cyber adversarial attacks that can potentially be launched against the communication links in the Cyber-Physical System (CPS). To enhance the security of KF-based state estimation, in this paper...

متن کامل

An Advanced State Estimation Method Using Virtual Meters

-  Power system state estimation is a central component in energy management systems of power system. The goal of state estimation is to determine the system status and power flow of transmission lines. This paper presents an advanced state estimation algorithm based on weighted least square (WLS) criteria by introducing virtual meters. For each bus of network, except slack bus, a virtual meter...

متن کامل

A Review on Protection of Transmission Lines

The growth of a country is scaled by the amount of energy it consumes. In the developing India, with the rise of population, increasing number of cities and demanding villages, caused to set up transmission lines with higher capacity. Inter-ties were connected through the transmission lines to lighten every city and village, thus making the whole system complex. This complex system required a r...

متن کامل

Software for Enhanced Monitoring in Integrated Substations

-Substation data integration is facilitated by existence and appropriate connection of Intelligent Electronic Devices (IEDs). Collecting data from IEDs and its processing facilitates performing data consistency checks, filtering out erroneous measurements, monitoring of switching sequences and substation topology transitions etc. Processed data may be used locally and/or communicated to remote ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003