SU-E-T-554: PTV to Skin Proximity for Head and Neck IMRT Treatment Planning.
نویسندگان
چکیده
PURPOSE The goal of this work was to evaluate measured vs. calculated surface dose as a function of PTV-to-skin proximity and calculation matrix oxel size, determine effects on plan quality, and provide parameters and levels of uncertainty for clinical use. METHODS A right-sided CTV with the lateral border 5mm from the surface was delineated on the CT data of a head and neck phantom. A 5mm PTV was generated except laterally where distances of 0-5mm were used. A 7-field IMRT plan was generated using the Eclipse TPS. Optimization was performed where 95% of the PTV receives the prescription dose using a matrix size of 2mm3 . Dose calculations were repeated for grid sizes of 1, 3 and 5mm3 . For each plan nine point dose values were obtained just inside the phantom surface, corresponding to a 2cm2 grid near the central target region. Nine ultra-thin TLDs were placed on the phantom surface corresponding to the grid. Measured and calculated dose values were compared. Conformality, homogeneity and target coverage were compared. RESULTS Surface dose is over-estimated by the TPS by 21 and 8% for 5 and 3mm3 voxels, respectively and accurately predicted for 2mm3 voxels. A voxel size of 1mm3 results in underestimation of 13%. Conformality improves with increasing PTV to skin distance and a CI of unity results for grid sizes of 1-3mm3 between 4 and 4.5mm. Hot spot decreases as the PTV moves away from the surface and falls below 110% at 4mm. Underdosage worsens as the PTV approaches the skin. CONCLUSIONS For decreasing PTV-to-skin distance with this TPS, isodose conformality decreases, 'hot spot' increases, and target coverage degrades. Surface dose is accurately predicted for a 2mm3 voxel size, while choosing a finer or coarser grid results in underestimation or overestimation, respectively. All of the above appear to hold for VMAT.
منابع مشابه
SU-E-T-593: Clinical Evaluation of Direct Aperture Optimization in Head/Neck and Prostate IMRT Treatment.
PURPOSE To investigate the planning and dosimetric advantages of direct aperture optimization (DAO) over beam-let optimization in IMRT treatment of head and neck (H/N) and prostate cancers. METHODS Five Head and Neck as well as five prostate patients were planned using the beamlet optimizer in Elekta-Xio ver 4.6 IMRT treatment planning system. Based on our experience in beamlet IMRT optimizat...
متن کاملImpact of geometric uncertainties on dose distribution during intensity modulated radiotherapy of head-and-neck cancer: the need for a planning target volume and a planning organ-at-risk volume
We assessed the effect of geometric uncertainties on target coverage and on dose to the organs at risk (OARS) during intensity-modulated radiotherapy (IMRT) for head-and-neck cancer, and we estimated the required margins for the planning target volume (PTV) and the planning organ-at-risk volume (PRV). For eight head-and-neck cancer patients, we generated IMRT plans with localization uncertainty...
متن کاملOptimization strategies for pulsed low‐dose‐rate IMRT of recurrent lung and head and neck cancers
Pulsed low-dose-rate radiotherapy (PLDR) has been proven to be a valid method of reirradiation. Previous studies of recurrent cancer radiotherapy were mainly based on conventional 3D CRT and VMAT delivery techniques. There are difficulties in IMRT planning using existing commercial treatment planning systems (TPS) to meet the PLDR protocol. This work focuses on PLDR using ten-field IMRT and a c...
متن کاملUsing overlap volume histogram and IMRT plan data to guide and automate VMAT planning: a head-and-neck case study.
PURPOSE To investigate whether an overlap volume histogram (OVH)-driven planning application using an intensity-modulated radiation therapy (IMRT) database can guide and automate volumetric-modulated arc therapy (VMAT) planning for head-and-neck cancer. METHODS Based on comparable head-and-neck dosimetric results between planner-generated VMAT and IMRT plans, an inhouse developed, OVH-driven ...
متن کاملA Comparative Study of Volumetric Intensity Modulated Arc Therapy Versus Conventional IMRT in Head and Neck Cancer Patients
Background: Intensity-modulated radiation therapy (IMRT) is now the method of choice for the treatment of patients with complex-shaped planning target volumes (PTV) targets, especially when concave targets are close to a larger number of organs-at-risk (OAR) as in patients with advanced head and neck cancer. Patients and Methods: Fifteen patients with advanced head and neck cancers (oropharynx,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 39 6Part18 شماره
صفحات -
تاریخ انتشار 2012