A Comparison of Relative Time to Peak and Tmax for Mismatch-Based Patient Selection

نویسندگان

  • Anke Wouters
  • Søren Christensen
  • Matus Straka
  • Michael Mlynash
  • John Liggins
  • Roland Bammer
  • Vincent Thijs
  • Robin Lemmens
  • Gregory W. Albers
  • Maarten G. Lansberg
چکیده

BACKGROUND AND PURPOSE The perfusion-weighted imaging (PWI)/diffusion-weighted imaging (DWI) mismatch profile is used to select patients for endovascular treatment. A PWI map of Tmax is commonly used to identify tissue with critical hypoperfusion. A time to peak (TTP) map reflects similar hemodynamic properties with the added benefit that it does not require arterial input function (AIF) selection and deconvolution. We aimed to determine if TTP could substitute Tmax for mismatch categorization. METHODS Imaging data of the DEFUSE 2 trial were reprocessed to generate relative TTP (rTTP) maps. We identified the rTTP threshold that yielded lesion volumes comparable to Tmax > 6 s and assessed the effect of reperfusion according to mismatch status, determined based on Tmax and rTTP volumes. RESULTS Among 102 included cases, the Tmax > 6 s lesion volumes corresponded most closely with rTTP > 4.5 s lesion volumes: median absolute difference 6.9 mL (IQR: 2.3-13.0). There was 94% agreement in mismatch classification between Tmax and rTTP-based criteria. When mismatch was assessed by Tmax criteria, the odds ratio (OR) for favorable clinical response associated with reperfusion was 7.4 (95% CI 2.3-24.1) in patients with mismatch vs. 0.4 (95% CI 0.1-2.6) in patients without mismatch. When mismatch was assessed with rTTP criteria, these ORs were 7.2 (95% CI 2.3-22.2) and 0.3 (95% CI 0.1-2.2), respectively. CONCLUSION rTTP yields lesion volumes that are comparable to Tmax and reliably identifies the PWI/DWI mismatch profile. Since rTTP is void of the problems associated with AIF selection, it is a suitable substitute for Tmax that could improve the robustness and reproducibility of mismatch classification in acute stroke.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of computed tomography perfusion and magnetic resonance imaging perfusion-diffusion mismatch in ischemic stroke.

BACKGROUND AND PURPOSE Perfusion imaging has the potential to select patients most likely to respond to thrombolysis. We tested the correspondence of computed tomography perfusion (CTP)-derived mismatch with contemporaneous perfusion-diffusion magnetic resonance imaging (MRI). METHODS Acute ischemic stroke patients 3 to 6 hours after onset had CTP and perfusion-diffusion MRI within 1 hour, be...

متن کامل

Delay-dependent stability for transparent bilateral teleoperation system: an LMI approach

There are two significant goals in teleoperation systems: Stability and performance. This paper introduces an LMI-based robust control method for bilateral transparent teleoperation systems in presence of model mismatch. The uncertainties in time delay in communication channel, task environment and model parameters of master-slave systems is called model mismatch. The time delay in communicatio...

متن کامل

Refining the perfusion-diffusion mismatch hypothesis.

BACKGROUND AND PURPOSE The Echoplanar Imaging Thrombolysis Evaluation Trial (EPITHET) tests the hypothesis that perfusion-weighted imaging (PWI)-diffusion-weighted imaging (DWI) mismatch predicts the response to thrombolysis. There is no accepted standardized definition of PWI-DWI mismatch. We compared common mismatch definitions in the initial 40 EPITHET patients. METHODS Raw perfusion image...

متن کامل

Comparison of 10 TTP and Tmax estimation techniques for MR perfusion-diffusion mismatch quantification in acute stroke.

BACKGROUND AND PURPOSE The mismatch between lesions identified in perfusion- and diffusion-weighted MR imaging is typically used to identify tissue at risk of infarction in acute stroke. The purpose of this study was to analyze the variability of mismatch volumes resulting from different time-to-peak or time-to-maximum estimation techniques used for hypoperfused tissue definition. MATERIALS A...

متن کامل

MR mismatch and thrombolysis: appealing but validation required.

Since the initial description of the ischemic penumbra 30 years ago, the concept of rapid restoration of blood flow to threatened brain tissue has been the “holy grail” of acute stroke therapy.1,2 Despite its drawbacks, MR imaging of perfusion diffusion mismatch remains the most widely used and practical means of in vivo assessment. There is accumulating evidence linking reperfusion with better...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2017