UV effects in tooth enamel and their possible application in EPR dosimetry with front teeth.
نویسندگان
چکیده
The effects of ultraviolet (UV) radiation on ionizing radiation biodosimetry were studied in human tooth enamel samples using the technique of electron paramagnetic resonance (EPR) in X-band. For samples in the form of grains, UV-specific EPR spectra were spectrally distinct from those produced by exposure to gamma radiation. From larger enamel samples, the UV penetration depth was determined to be in the 60-120 mum range. The difference in EPR spectra from UV exposure and from exposure to gamma radiation samples was found to be a useful marker of UV equivalent dose (defined as the apparent contribution to the gamma dose in mGy that results from UV radiation absorption) in tooth enamel. This concept was preliminarily tested on front teeth from inhabitants of the region of the Semipalatinsk Nuclear Test Site (Kazakhstan) who might have received some exposure to gamma radiation from the nuclear tests conducted there as well as from normal UV radiation in sunlight. The technique developed here to quantify and subtract the UV contribution to the measured tooth is currently limited to cumulative dose measurements with a component of UV equivalent dose equal to or greater than 300 mGy.
منابع مشابه
Comparison Between Deciduous And Permanent Teeth in Relation to their Utility for EPR Dosimetry Comparison Between Deciduous And Permanent Teeth in Relation to their Utility for EPR Dosimetry
Introduction Ionizing radiation generates extremly long lived CO2 radicals in calcified tissue. The CO2 concentration rises linearly with dose and can be detected directly by means of EPR spectroscopy (electron paramagnetic resonanc). For retrospective dose estimation tooth enamel and dentine as well as bone samples may be used as in-vivo-dosimeter. Enamel analysis of permanent teeth has been e...
متن کاملEnhanced EPR Dose Reconstruction in Teeth
Currently electron paramagnetic resonance (EPR) retrospective biodosimetry with tooth enamel can measure doses as low as 30 mGy. This method uses commercial X-band (9.5 GHz) EPR spectrometers and specially prepared samples from tooth enamel. One of the disadvantages of X-band EPR dosimetry is the requirement to obtain isolated teeth from a cohort of interest. In vivo EPR retrospective biodosime...
متن کاملHuman EPR Dosimetry at Low Accumulated Dose of Ionizing Radiation Human EPR Dosimetry at Low Accumulated Dose of Ionizing Radiation
A new method for tooth (enamel and dentine) and bone EPR dosimetry is proposed that enhances substantially the dosimetric sensitivity. The method is based on the nonstandard spectra registration mode (the second harmonic phase quadrature detection of absorption under rapid passage conditions). This method provides an apparent enhancement of the component ratio of radiation to a nonradiative bac...
متن کاملThe 4th international comparison on EPR dosimetry with tooth enamel Part 1: Report on the results
This paper presents the results of the 4th International Comparison of in vitro electron paramagnetic resonance dosimetry with tooth enamel, where the performance parameters of tooth enamel dosimetry methods were compared among sixteen laboratories from all over the world. The participating laboratories were asked to determine a calibration curve with a set of tooth enamel powder samples provid...
متن کاملRetrospective dosimetry using fingernail in nuclear industries: A review paper
Generally, doses greater than 2Gy can produce acute biological effects in humans. For this reason, to measure and record the cumulative dose, especially in radiation users, the need for a personal dosimeter has been strongly felt by the researchers. The purpose of this study is to introduce retrospective dosimetric techniques, in particular the use of nails as a natural tool for determining cum...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Health physics
دوره 98 2 شماره
صفحات -
تاریخ انتشار 2010