Effect on Substation Engineering Costs of IEC 61850 and System Configuration Tools

نویسنده

  • Adam Gauci
چکیده

Change management, software configuration training, and human error all impact the cost associated with substation automation engineering. Object-oriented engineering approaches as defined in the IEC 61850 standard represent significant cost savings when compared to traditional methods using hardwire and Distributed Network Protocol (DNP3). New multivendor system configuration tools are described that further reduce substation automation engineering costs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

IEC 61850 Engineering Process and Multi-Vendor System Configuration Tools Reduce Engineering Costs of Substation Automation Projects

........................................................................................................

متن کامل

Comparative Reliability Analysis of Substation Automation Architecture Based on IEC 61850 Standard

Using IEC 61850 standard would increase the reliability and availability of electricity network and put a huge impact on network automation. Even though much research works has been done in substation system reliability, there is a few works in automated substation control system reliability. This paper evaluates the reliability of substation automation system based IEC 61850 comparatively cons...

متن کامل

Iec 61850 Scl - More than Interoperable Data Exchange between Engineering Tools

The IEC 61850 SCL language for Substation Configuration description is standardized for the interoperable exchange of engineering data between engineering tools. Its model based approach allows to use it also for other purposes. As an illustration this paper explores some examples, like usage for storage of protection parameters, maintenance support, control center gateway engineering, and appl...

متن کامل

Real Time Simulation Testing Using IEC 61850

-As IEC 61850 becomes more widely accepted in the electrical engineering community, it is important that the testing tools keep pace with this development. IEC 61850 presents new challenges to real time simulation and closed-loop testing of protective relays. Electrical interfaces used for binary signaling and voltage/current amplifiers must be replaced by an Ethernet connection and an IEC 6185...

متن کامل

Template Based Engineering of Substation Automation Systems with the Iec 61850 Functional Naming Concept

The creation of the data model and the configuration of the communication system represent essential tasks of engineering substation automation systems With SCL (Substation Configuration Description Language) the system standard IEC 61850 provides a standardized formal representation of the data model and communication configuration of substation automation systems. The substation model of SCL ...

متن کامل