One-Year Outcome of Everolimus-Eluting Stents Versus Biolimus-Eluting Stents in Patients Undergoing Percutaneous Coronary Intervention

نویسندگان

  • Mohammad Alidoosti
  • Vahideh Sharifnia
  • Seyed Ebrahim Kassaian
  • Alimohammad Hajizeinali
  • Hamidreza Poorhosseini
  • Mojtaba Salarifar
  • Younes Nozari
  • Elham Hakki Kazazi
چکیده

Background: The biolimus-eluting stent (BES), with a biodegradable polymer, has not been previously compared with the everolimus-eluting stent (EES), as a second-generation drug-eluting stent (DES).We sought to compare the 1-year outcome between the PROMUS™ stent (EES type) and the BioMatrix™ stent (BES type). Methods: From March 2008 to September 2011, all patients treated with the PROMUS™ stent or the BioMatrix™ stent for coronary artery stenosis at Tehran Heart Center were enrolled. The primary end points were 1-year adverse events, comprising death, myocardial infarction, target vessel revascularization, and target lesion revascularization. The secondary end point was stent thrombosis. The Cox proportional hazard model was used to assess the adjusted association between the stent type and the follow-up outcome. Results: From 949 patients (66.3% male, mean age =59.48 ± 10.46 y) with 1,018 treated lesions, 591 patients (630 lesions, 65.1% male, mean age = 59.24 ± 10.23 y) received the PROMUS™ stent and 358 patients (388 lesions, 68.2% male, mean age = 59.88 ± 10.83 y) were treated with the BioMatrix™ stent. Before adjustment, the rate of the primary end points was 3.2% and 3.4% in the EES and BES, respectively (p value = 0.925, HR (EES to BES) = 1.035, 95% CI: 0.50 to 2.13). The rate of stent thrombosis was 2% and 1.7% in the EES and BES, respectively (p value = 0.698). After adjustment on confounder variables, there was no statistically significant difference in major adverse cardiac events between the PROMUS™ stent and the BioMatrix™ stent (p value = 0.598, HR (EES to BES) = 0.817, 95% CI: 0.39 to 1.73). Conclusion: At 1 year's follow-up, the BES and EES showed similar safety and efficacy rates in the patients undergoing percutaneous coronary intervention with a relatively low rate of adverse events in the 2 groups.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of biolimus-eluting stents with biodegradable polymer vs bare-metal stents on cardiovascular events among patients with acute myocardial infarction: the COMFORTABLE AMI randomized trial.

CONTEXT The efficacy and safety of drug-eluting stents compared with bare-metal stents remains controversial in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PCI). OBJECTIVE To compare stents eluting biolimus from a biodegradable polymer with bare-metal stents in primary PCI. DESIGN, SETTING, AND PATIENTS A prospectiv...

متن کامل

Differential clinical responses to everolimus-eluting and Paclitaxel-eluting coronary stents in patients with and without diabetes mellitus.

BACKGROUND Some (but not all) prior trials have reported differential outcomes after percutaneous coronary intervention with paclitaxel-eluting stents versus stents eluting rapamycin analogs according to the presence of diabetes mellitus. These studies lacked sufficient power to examine individual safety and efficacy end points. METHODS AND RESULTS To determine whether an interaction exists b...

متن کامل

Everolimus-Eluting versus Paclitaxel-Eluting Stents in Percutaneous Coronary Intervention: Meta-Analysis of Randomized Trials

Background. Individual randomized trials have suggested that everolimus-eluting stents may have improved clinical outcomes compared to paclitaxel-eluting stents, but individual trials are underpowered to examine outcomes such as mortality and very late stent thrombosis. Methods. Medline, Cochrane, and conference proceedings were searched for randomized trials comparing everolimus versus paclita...

متن کامل

New-generation drug-eluting stent experience in the percutaneous treatment of unprotected left main coronary artery disease: the NEST registry.

OBJECTIVES To explore the 2-year clinical outcomes in patients with unprotected left main coronary artery (ULMCA) disease treated with overall new drug-eluting stent (DES) options. BACKGROUND Recent available data have shown the feasibility and the safety of new DESs, mainly evaluating the everolimus-eluting stents in the setting of ULMCA disease. METHODS Patients with ULMCA disease undergo...

متن کامل

Clinical outcomes of biodegradable polymer biolimus-eluting BioMatrix stents versus durable polymer everolimus-eluting Xience stents

There are limited data about clinical outcomes of biodegradable polymer biolimus-eluting BioMatrix stents (BP-BES) and durable polymer everolimus-eluting Xience stents (DP-EES) in real world practice. We sought to compare the clinical outcomes of BP-BES and DP-EES in real world cohorts of patients undergoing percutaneous coronary intervention. A prospective multicenter registry enrolled 999 pat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016