Impact of intelligent phacoemulsification software on torsional phacoemulsification surgery

نویسندگان

  • Silay Canturk Ugurbas
  • Sinan Caliskan
  • Atilla Alpay
  • Suat Hayri Ugurbas
چکیده

BACKGROUND The purpose of this study was to compare phacoemulsification energy parameters during torsional phacoemulsification with or without the use of intelligent phacoemulsification (IP) software. METHODS One hundred and twenty-eight eyes with nuclear grades ranging from 1 to 5 were enrolled in this randomized prospective study. Operated eyes were divided into two groups, ie, those operated on using IP software (Group 1, n = 67) and those operated on without IP software (Group 2, n = 61). The two groups were compared in terms of ultrasound energy level, ultrasound energy time, aspiration time, and amount of fluid used during surgery. RESULTS Operated eyes were further grouped according to soft (grade 1 and 2, n = 37), medium (grade 3, n = 46), and hard (grade 4 and 5, n = 31) nuclear densities. Both the study and the control groups were similar in distribution of nuclear density (P > 0.05). Cumulative dissipated energy was measured as 14.06 ± 9.92 in Group 1 and 14.22 ± 10.99 in Group 2 (P = 0.92). Total ultrasound time was 49 seconds in Group 1 and 52 seconds in Group 2 (P = 0.58). Although the torsional amplitude used was similar (P = 0.86) when IP was either on (71%) or off (68.4%), aspiration time was found to be 4 minutes 17 seconds in Group 1 (P = 0.86) and 5 minutes and 17 seconds in Group 2 (P = 0.007). Total fluid used was measured as 91 cc (P = 0.86) in Group 1 and 109 cc (P = 0.02) in Group 2. CONCLUSION The new IP software did not cause a difference in ultrasound energy levels. However, the new software was found to be advantageous in regards to fluid use and aspiration time.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

TORSIONAL AND MICRO-COAXIAL TECHNOLOGY: New Efficiencies in Challenging Cases

I would like to present our experiences with torsional and micro-coaxial technology on behalf of our French research group. My goal is to demonstrate to surgeons the transition from performing phacoemulsification with traditional longitudinal ultrasound to a micro-coaxial procedure using torsional technology. The impetus for the development of micro-incisional phacoemulsification was to provide...

متن کامل

Effect of torsional mode phacoemulsification on cornea in eyes with/without pseudoexfoliation.

AIM To evaluate the effect of torsional mode phacoemulsification on central corneal thickness, corneal endothelial cell density, and morphology in eyes with/without pseudoexfoliation (PEX) syndrome. METHODS Fourty-two consecutive patients with and 42 patients without PEX as a control group scheduled for cataract surgery was studied. Phacoemulsification, using OZiL IP system, was performed wit...

متن کامل

Comparative analysis of corneal morphological changes after transversal and torsional phacoemulsification through 2.2 mm corneal incision

PURPOSE This paper compares and evaluates the corneal morphological changes occurring after cataract surgery through a 2.2 mm corneal incision. We use two platforms for comparison and evaluation, transversal and torsional phacoemulsification. PATIENTS AND METHODS This study includes 139 consecutive cataractous eyes (nuclear color 2-4, according to the Lens Opacities Classification System III ...

متن کامل

Thermal imaging comparison of Signature, Infiniti, and Stellaris phacoemulsification systems

BACKGROUND To compare the heat production of 3 different phacoemulsification machines under strict laboratory test conditions. More specifically, the thermal behavior was analyzed between the torsional modality of the Infiniti system and longitudinal modalities of the Abbot WhiteStar Signature Phacoemulsification system and Bausch and Lomb Stellaris system. METHODS Experiments were performed ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2012