The optically-guided frameless system (OFLS) has been used in our clinic for intracranial stereotactic radiosurgery (SRS) since 2006, as it is especially effective in IMRT-based radiosurgery (IMRS), which allows treating multiple brain lesions simultaneously using single isocenter approach. This study reports our retrospective analysis of patient setup accuracy using this system. The OFLS consists of a bite block with fiducial markers and an infra-red camera system. To test reproducibility, patients are taken for reseat verification after bite block construction. Upon the completion of radiosurgery planning, the isocenter position(s) and images are sent to the optical guidance computer where fiducials are manually registered from the CT scan. During treatment, patient setup is monitored and guided by the camera readings on the fiducials. In addition, two orthogonal kV images are acquired and used as an isocenter verification tool. In addition, we have analyzed the reseat and fiducial digitization data of 56 patients. Retrospective comparison of kV images with reference images has been carried out for all the patients to evaluate actual patient setup accuracy at the time of treatment. The histogram of the findings shows that 82.2% of patients had 3D isodisplacement (E < or = 1 mm; 5.2% had 1< E < or = 2 mm). Hence, for 87.5 % of the patients in the study, treatments were finished under the optical guidance with a maximum setup error of 2 mm and the median setup error of 0 mm. For the remaining 12.5% of patients in the study, the isodisplacements were greater than 2 mm and the treatment records showed that those patients were repositioned, guided by the orthogonal kV-images. It is found that the OFLS in the SRS treatment has acceptable accuracy when used in conjunction with orthogonal kV images, and the use of orthogonal kV images as a verification tool ensures the efficacy of frameless localization in the radiosurgery treatment.
منابع مشابه
Importance of CBCT setup verification for optical‐guided frameless radiosurgery
The purpose of this study is to quantify the discrepancy between optical guidance platform (OGP) frameless localization system (Varian) and Trilogy on-board imaging (OBI) system (Varian) for setting up phantom and stereotactic radiosurgery (SRS) patient; and to determine whether cone-beam CT (CBCT) is necessary for OGP patient setup, and compare CBCT and orthogonal kV-kV in term of their verifi...
متن کاملCurrent status and optimal use of radiosurgery.
The field of stereotactic radiosurgery is rapidly advancing as a result of both improvements in radiosurgical equipment and better physician understanding of the clinical applications of stereotactic radiosurgery. This article will review recent developments in the field of radiosurgery, including advances in our understanding of the treatment of brain metastases and arteriovenous malformations...
متن کاملCyberKnife radiosurgery for spinal neoplasms.
The role of stereotactic radiosurgery for the treatment of intracranial lesions is well established. Its use for the treatment of spinal lesions has been limited by the availability of effective target immobilization and localization technologies. Conventional external beam radiotherapy lacks the precision to allow delivery of large doses of radiation near radiosensitive structures such as the ...
متن کاملFrameless Stereotactic Biopsy of Intracranial Lesions: Evaluation of Efficacy and Complications
Objective: Frameless stereotactic biopsy has been shown in multiple studies to be a safe and effective procedure for the diagnosis of brain lesion. In this study the authors will evaluate the safety of the procedure and associated complications including neurological deficits in our set up of developing countries. Methods: Forty two patients with different brain lesions were biopsied using fram...
متن کاملClinical experience with two frameless stereotactic radiosurgery (fSRS) systems using optical surface imaging for motion monitoring
The purpose of this study was to compare two clinical immobilization systems for intracranial frameless stereotactic radiosurgery (fSRS) under the same clinical procedure using cone-beam computed tomography (CBCT) for setup and video-based optical surface imaging (OSI) for initial head alignment and intrafractional motion monitoring. A previously established fSRS procedure was applied using two...