The effect of modular tapered fluted stems on proximal stress shielding in the human femur.

نویسندگان

  • William P Hnat
  • Justin S Conway
  • Arthur L Malkani
  • Madhu R Yakkanti
  • Michael J Voor
چکیده

The purpose of this study was to show a change in proximal femur surface strains following total hip arthroplasty and after the addition of BoneSource hydroxyapatite bone cement in the proximal region of an instrumented femur and to measure the surface strain on the proximal body. Seven third-generation composite femurs (Pacific Research Laboratories, Vashon, Wash) were instrumented with 12 uniaxial strain gages, 6 gages on the anterior face, and 6 gages on the posterior face of each femur. All femurs exhibited stress shielding since the strains in the proximal region were drastically reduced. There was a large decrease in strain in the mid-shaft region and small changes in strain in the distal region. The surface strains on the modular implant were relatively low.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Revision total hip arthroplasty in patients with extensive proximal femoral bone loss using a fluted tapered modular femoral component.

Revision total hip arthroplasty (THA) is challenging when there is severe loss of bone in the proximal femur. The purpose of this study was to evaluate the clinical and radiographic outcomes of revision THA in patients with severe proximal femoral bone loss treated with a fluted, tapered, modular femoral component. Between January 1998 and December 2004, 92 revision THAs were performed in 92 pa...

متن کامل

Modular tapered titanium stems in revision arthroplasty of the hip: The Risk and Causes of Stem Fracture.

Tapered fluted titanium stems are increasingly used for femoral revision arthroplasty. They are available in modular and non-modular forms. Modularity has advantages when the bone loss is severe, the proximal femur is mis shapen or the surgeon is unfamiliar with the implant, but it introduces the risk of fracture of the stem at the junction between it and the proximal body segment. For that rea...

متن کامل

Managing femoral bone loss in revision total hip replacement: fluted tapered modular stems.

If a surgeon is faced with altered lesser trochanter anatomy when revising the femoral component in revision total hip replacement, a peri-prosthetic fracture, or Paprosky type IIIb or type IV femoral bone loss, a modular tapered stem offers the advantages of accurately controlling femoral version and length. The splines of the taper allow rotational control, and improve the fit in femoral cana...

متن کامل

Bone density study of the proximal femur after hip arthroplasty with porous-coated implants

Progressive loss of bone mineral density around the femora! component of total hip replacement continues to pose a threat to long term prosthetic survival. A linear study was undertaken to measure bone mineral density on a monthly basis following total hip arthroplasty in 11 male patients. The opposite femur was used as the control measurement. Bone mineral density was unchanged at two mo...

متن کامل

Stubby stems: good things come in small packages.

Standard-length porous-coated tapered femoral stems perform exceedingly well in primary total hip arthroplasty (THA) at long-term follow-up. Nevertheless, there are multiple reasons to strongly consider the relatively new concept of short tapered stems. First, there is already a wide variation in the lengths of "standard" components and the ideal length is unknown. The goal of tapered stems is ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of arthroplasty

دوره 24 6  شماره 

صفحات  -

تاریخ انتشار 2009