Feasibility of Using Predicted Cramer Rao Lower Bounds for the Design of Optimized In Vivo MR Spectroscopy Sequences Targeting Multiple Metabolites
نویسندگان
چکیده
Introduction Quantitation of metabolites by H MRS is fundamentally complicated by signal overlap. Fitting short TE spectra with the use of prior knowledge of metabolite spectra (linear combination model fitting, LCMF) is one way to ease this problem. The use of editing sequences for exclusive recording of signals from single metabolites is an alternative route to gain more accurate metabolite information. The former approach does not achieve the accuracy of the latter, where signal overlap for selected parts of the metabolite spectrum is eliminated as much as possible. The second approach has the significant disadvantage that information on most metabolites is sacrificed for accuracy on a single one. The achievable accuracy in fitting can be judged by the Cramer-Rao minimum variance bounds (CRB), which depend entirely on the fit model (i.e. constituting metabolites and their relative concentrations as well as the type of MR experiment) and the signal to noise, but not the actual experimental spectrum. It is therefore possible to compare the achievable accuracy for any metabolite in any MR experiment without ever implementing and performing it if the spectra can be simulated and we have a reasonable idea of tissue composition. In this work we demonstrate the feasibility of using CRB for design optimization of localized H MR sequences. This has been done previously in other areas of MR (e.g. high resolution NMR [1], diffusion MR [2]). As a simple demonstration example it was tested which parameter setup in PRESS and STEAM experiments would be best for optimal accuracy of glutamate (Glu) and glutamine (Gln). Methods and Subjects Spectra were simulated using the framework of GAMMA [3] for STEAM and PRESS sequences with ideal pulses, as previously implemented in the GAVA interface [4]. The dependence of CRB for Gln and Glu amplitudes on two parameters was investigated for 3 field strengths (1.5T, 3T, 7T). For PRESS, 1 and 2 echo times were incremented from 0 to 288 ms. For STEAM, TE and TM were varied. Following Ref [5], CRB were calculated for LCMF of Glu and Gln at equal concentrations, specific linewidths and SNR, which was made TE dependent using T2’s from the literature. Results & Discussion CRB can be calculated in the available parameter space of a given MR sequence, as illustrated in Fig. 1 for Glu and Gln in PRESS. In this example, longer TE yield generally higher CRB because of T2 signal decay. But the graphs show that ridges are followed by troughs with relatively better performance. In specific editing sequences the T2 decay will not dominate the overall minimum and optimal parameters can be chosen to minimize CRB for selected metabolites. Fig. 2 shows spectra for the same overall TE where the simulations predict much better performance for area estimation in one parameter combination than the other. The examples show that it is indeed feasible to optimize experiments for detection of specific metabolites using spectral simulation and CRB as criterion. This approach is promising for both optimization of general experiments, and also specific editing methods that can be combined with LCMF, where CRB will yield a criterion for optimal detection based on the full spectrum, not selected regions as usually targeted in editing [6]. This work clearly provides a proof of principle only for the design of new experiments and the examples serve as illustrations. Useful new experiments can be obtained after removing the severe restrictions that have not been addressed here. Shortcomings in the current implementation include: 1) Use of ideal experiments (RF bandwidth, flip angles), 2) Only 2 metabolites considered, 3) Neglect of baseline, which can severely affect calculation of CRB [7]. Further extensions will also include more sophisticated experiments, like use of MQ filters, selective pulses, or 2D experiments. Conclusion CRB provide design criteria for optimized in vivo MRS scans using complete metabolite spectra in combination with LCMF. This should yield higher accuracy for ranges of targeted metabolites without complete loss of information on other compounds. References 1. Ober R. et al. J Magn Reson 157:1 (2002); 2. Brihuega-Moreno O. et al. Magn Reson Med 50:1069 (2003); 3. Smith SA et al. J Magn. Reson 106A:75 (1994); 4. Maudsley AA et al. J Magn Reson 173:54 (2005); 5. Cavassila S et al. NMR in Biomed 14:278 (2001); 6. Yang S et al. 14 ISMRM p.492 (2006); 7. Van Ormondt D. Role of CRB's in a semi-parametric context. ISMRM workshop on signal processing, Warrenton, (2006) We thank Andrew Maudsley (Miami) and Brian Soher (Duke) for providing GAVA and its support. Funded by the Swiss National Foundation (3100A0-103938). Fig. 2: Simulated PRESS spectra for Glu (blue) and Gln (red), at TE 288, but different TE1 and TE2 combinations to obtain minimum (a, 38%, TE1 198ms , TE2 90 ms) and maximum (b, 60%, TE1 72ms , TE2 216 ms) CRB for Gln (similar behavior for Glu).
منابع مشابه
Improved Cramer-Rao Inequality for Randomly Censored Data
As an application of the improved Cauchy-Schwartz inequality due to Walker (Statist. Probab. Lett. (2017) 122:86-90), we obtain an improved version of the Cramer-Rao inequality for randomly censored data derived by Abdushukurov and Kim (J. Soviet. Math. (1987) pp. 2171-2185). We derive a lower bound of Bhattacharya type for the mean square error of a parametric function based on randomly censor...
متن کاملOn the use of Cramér-Rao minimum variance bounds for the design of magnetic resonance spectroscopy experiments
Localized Magnetic Resonance Spectroscopy (MRS) is in widespread use for clinical brain research. Standard acquisition sequences to obtain one-dimensional spectra suffer from substantial overlap of spectral contributions from many metabolites. Therefore, specially tuned editing sequences or two-dimensional acquisition schemes are applied to extend the information content. Tuning specific acquis...
متن کاملEnhanced neurochemical profile of the rat brain using in vivo (1)H NMR spectroscopy at 16.4 T.
Single voxel magnetic resonance spectroscopy with ultrashort echo time was implemented at 16.4 T to enhance the neurochemical profile of the rat brain in vivo. A TE of 1.7 msec was achieved by sequence optimization and by using short-duration asymmetric pulses. Macromolecular signal components were parameterized individually and included in the quantitative analysis, replacing the use of a meta...
متن کاملDevelopmental and regional changes in the neurochemical profile of the rat brain determined by in vivo 1H NMR spectroscopy.
Sixteen metabolites were quantified from 11-24 micro l volumes in three different brain regions (hippocampus, striatum, and cerebral cortex) during postnatal development. Rat pups from the same litter were repeatedly measured on postnatal days 7, 10, 14, 21, and 28 using a completely noninvasive and longitudinal study design. Metabolite quantification was based on ultra-short echo-time (1)H NMR...
متن کاملIn-vitro – In-vivo Characterization of Glimepiride Lipid Nanoparticulates Prepared by Combined Approach of Precipitation and Complexation
Novel lipid nanoparticulates (NCs) were developed by a combined approach of precipitation and complexation with an aim to improve the solubility, stability and targeting efficiency of glimepiride (GLP). GLP NCs were prepared by precipitation process using PEG 20000 and further complexed with phospholipon90G (P90G). The NCs were evaluated for physicochemical characterization, such as drug lo...
متن کامل