Comparison of blue dye and probe-assisted intraoperative lymphatic mapping in melanoma to identify sentinel nodes in 100 lymphatic basins.

نویسندگان

  • P Bostick
  • R Essner
  • E Glass
  • M Kelley
  • T Sarantou
  • L J Foshag
  • K Qi
  • D Morton
چکیده

OBJECTIVE To determine whether combining isosulfan blue dye with a radiopharmaceutical agent will increase intraoperative detection of sentinel nodes (SNs) in patients with early-stage melanoma. PATIENTS AND DESIGN Clinical trial with a consecutive sample. Eighty-seven patients with clinical stage I melanoma underwent preoperative lymphoscintigraphy with 1 of 3 radiopharmaceutical agents to identify the lymphatic basin and the site of the SN. All patients subsequently underwent intraoperative lymphatic mapping and selective lymph node dissection (SLND) with isosulfan blue dye and a radiopharmaceutical agent. A handheld gamma probe determined the radioactive counts over the draining lymph node basins and individual blue-stained lymph nodes before (in vivo) and after (ex vivo) their removal. An irrelevant body site was used as the denominator of a count ratio by which absolute counts were standardized for comparison. Completion lymphadenectomy was undertaken in patients whose SLND specimen had histopathologic evidence of tumor cells. SETTING Tertiary care cancer center. INTERVENTION Lymph node sampling. MAIN OUTCOME MEASURE Accuracy of SN detection by blue dye and radiopharmaceutical techniques. RESULTS Preoperative lymphoscintigraphic images identified 100 lymph node basins and 135 lymph nodes in 87 patients. All 3 radiopharmaceutical agents were equally effective in imaging the SN before surgery. During SLND, we identified and removed 136 blue-stained and radioactive (hot) SNs and 8 additional non-blue-stained hot nodes from 98 basins (98.0%). Of the 144 excised lymph nodes, 132 nodes (91.7%) from 83 basins had either an in vivo- or an ex vivo-background count ratio of 2:1 or more and 125 nodes (86.8%) from 77 basins had a count ratio of 3:1 or more. Twelve blue-stained SNs had count ratios of less than 2:1. Seventeen SNs (11.8%) from 15 basins contained metastases: 16 were identified with blue dye and probe and 1 was identified with blue dye alone. Four (1.1%) of 377 non-SNs excised during completion lymphadenectomy contained metastases. There have been no lymph node recurrences during mean follow-up of 16.3 months (range, 7-42 months). CONCLUSIONS The blue dye technique remains the criterion standard for SLND in melanoma. The addition of a radiopharmaceutical tracer serves as a useful adjunct to the visualization of blue-stained SNs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sentinel lymph node biopsy correctly predicts regional lymph node recurrence in trunk malignant melanoma with multiple drainage basins

We report a young male with an initial excisional biopsy report of melanoma of the lower back, referred to our hospital for complete excision and sentinel lymph node (SLN) biopsy.  Four peritumoral intradermal Tc-99m phytate injection was performed and SLNs were detected in both axillary and right inguinal regions. On the biopsy only the right axillary SLN was metastatic leading to right axilla...

متن کامل

Lymphoscintigraphy and intraoperative lymphatic mapping of sentinel lymph nodes in melanoma patients.

Identification of sentinel lymph nodes (SLNs) using lymphoscintigraphy, the blue dye technique and intraoperative lymphatic mapping with a gamma-detecting probe has become the standard of care in diagnosing and treating melanoma. Numerous clinical studies have proven the reliability of predicting the histology of remaining lymph nodes in the lymphatic basin from the histologic evaluation of the...

متن کامل

Society of Nuclear Medicine Procedure Guideline for Lymphoscintigraphy and the Use of Intraoperative Gamma Probe for Sentinel Lymph Node Localization in Melanoma of Intermediate Thickness

A. This guideline is written specifically for lymphoscintigraphy in patients with primary melanomas that originate in the skin. Staging of these tumors is based on tumor thickness (Breslow measurement) and level of skin invasion (Clark’s level), both of which are determined by the pathologist from a biopsy sample. Ample data correlate patient survival with Breslow and Clark measurements. In the...

متن کامل

Vital dye is enough for inguinal sentinel lymph node biopsy in melanoma patients.

PURPOSE The importance of gamma probe detection (GPD) combined with vital dye for sentinel node (SN) biopsy is well accepted. We evaluated the efficacy of patent blue dye (PBD) in identifying inguinal SN. METHODS Ninety-four cutaneous melanoma patients with inferior extremity lesions were submitted to SNB according to a established protocol. Patients were randomized in two groups: Blue group,...

متن کامل

Is intra-operative gamma probe detection really necessary for inguinal sentinel lymph node biopsy?

CONTEXT Sentinel node (SN) biopsy has changed the surgical treatment of malignant melanoma. The literature has emphasized the importance of gamma probe detection (GPD) of the SN. OBJECTIVE Our objective was to evaluate the efficacy of patent blue dye (PBD) and GPD for SN biopsy in different lymphatic basins. DESIGN Patients with cutaneous malignant melanoma in stages I and II were submitted...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of surgery

دوره 134 1  شماره 

صفحات  -

تاریخ انتشار 1999