Inhaled corticosteroid delivery systems: clinical role of a breath-actuated device.

نویسنده

  • D Donnell
چکیده

Several devices have been developed to overcome the need to co-ordinate actuation with inhalation required during use of a pressurised metered dose inhaler (MDI) and to improve drug delivery to the lung. These include spacer attachments for MDIs, dry powder inhalers and breath-actuated MDIs. The breath-actuated Autohaler (3M Pharmaceuticals) is a compact, multidose inhaler device that, unlike dry powder inhalers, does not rely on the patient's inspiratory effort to aerosolise the dose of medication. Due to its simple operation, the Autohaler is suitable for patients unable to operate a conventional MDI efficiently, including the elderly, children, patients with arthritis and patients with low inspiratory flow rates. The mandatory replacement of chlorofluorocarbon propellants with non-ozone-depleting propellants has given the opportunity to improve drug delivery characteristics of MDIs. Recently, a formulation of beclomethasone dipropionate in hydrofluoroalkane-134a (HFA-BDP), has been developed in a conventional MDI that delivers most of the emitted dose to the lung. Drug deposition studies show that the HFA-BDP formulation in the Autohaler device has a similar lung deposition pattern to drug delivered from the MDI, when used correctly, and dose delivery is consistent across a wide range of inspiratory flow rates. Furthermore, HFA-BDP Autohaler has similar clinical benefits to CFC-BDP Autohaler but at less than half the dose. HFA-BDP Autohaler offers a useful CFC-free delivery option for patients challenged by the conventional MDI device.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimizing inhaled drug delivery in patients with asthma.

Successful management of asthmatic patients depends on achieving adequate delivery of inhaled drugs to the lung. This assumes particular importance for inhaled corticosteroids where the therapeutic goal should be to achieve a high ratio of airway anti-inflammatory efficacy to local and systemic side effects. The availability of user-friendly inhaler devices requires a critical appraisal of thei...

متن کامل

Systematic review of clinical effectiveness of pressurised metered dose inhalers versus other hand held inhaler devices for delivering corticosteroids in asthma.

OBJECTIVE To determine the clinical effectiveness of pressurised metered dose inhalers (with or without spacer) compared with other hand held inhaler devices for the delivery of corticosteroids in stable asthma. DESIGN Systematic review of randomised controlled trials. DATA SOURCES Cochrane Airways Group trials database (Medline, Embase, Cochrane controlled clinical trials register, and han...

متن کامل

Delivery of iloprost inhalation solution with the HaloLite, Prodose, and I-neb Adaptive Aerosol Delivery systems: an in vitro study.

BACKGROUND Iloprost (Ventavis) inhalation solution is approved in doses of 2.5 microg and 5.0 microg for treatment of pulmonary arterial hypertension (World Health Organization group I) in patients with New York Heart Association class III or IV symptoms, delivered with 2 Adaptive Aerosol Delivery (AAD) systems: Prodose and I-neb. The HaloLite device was the first-generation AAD system used in ...

متن کامل

Influence of nebulizer type with different pediatric aerosol masks on drug deposition in a model of a spontaneously breathing small child.

BACKGROUND The performance of nebulizers varies with the design type as well as the breathing patterns of various age groups. The present study quantified aerosol delivery using spontaneously breathing parameters of a small child (2-4 years) by a lung simulator to determine the influence of nebulizer type, actuation mechanisms, and pediatric aerosol masks. METHODS Three types of nebulizer (c...

متن کامل

Clinical evaluation of a simple demand inhalation MDI aerosol delivery device.

Inhalation of medication is the preferred method for treating reversible airway obstruction; however, difficulties in the use of pressurized canisters frequently lead to suboptimal results. The Aerochamber (Monoghan Medical Corp) is a portable breath-actuated device that attaches to a metered-dose inhaler (MDI) and is designed to overcome many of the problems of aerosol delivery encountered by ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European review for medical and pharmacological sciences

دوره 5 1  شماره 

صفحات  -

تاریخ انتشار 2001