Measurement of macular structure-function relationships using spectral domain-optical coherence tomography (SD-OCT) and pattern electroretinograms (PERG)

نویسندگان

  • Keunheung Park
  • Jinmi Kim
  • Jiwoong Lee
چکیده

BACKGROUND Retinal ganglion cell (RGC) death is a common cause of loss of vision during glaucoma. Pattern electroretinogram (PERG) is an objective measure of the central retinal function that correlates with macular GCL thickness. The aim of this study is to determine possible relationships between the N95 amplitude of pattern electroretinogram (PERGamp) and macular ganglion cell/inner plexiform layer thickness (GCIPLT). METHODS AND FINDINGS This was a retrospective and comparative study including 74 glaucoma patients (44 early stage and 30 advanced stage cases) and 66 normal control subjects. Macular GCIPLT was measured using Cirrus spectral domain-optical coherence tomography. Standard automated perimetry and pattern ERGs were used in all patient examinations. Three types of regression analysis (broken stick, linear regression, and quadratic regression) were used to evaluate possible relationships between PERGamp and GCIPLT. Correlations between visual field parameters and GCIPLT were evaluated according to glaucoma severity. The best fit model for the relationship between PERGamp and GCIPLT was the linear regression model (r2 = 0.22; P < 0.001). The best-fit model for the relationship between visual field parameters and GCIPLT was the broken stick model. During early glaucoma, macular GCIPLT was positively correlated with PERGamp, but not with visual field loss. In advanced glaucoma, macular GCIPLT was positively correlated with both PERGamp and visual field loss. CONCLUSIONS PERGamp was significantly correlated with macular GCIPT in early glaucoma patients, while visual field performance showed no correlation with GCIPLT. PERGamp can therefore assist clinicians in making an early decision regarding the most suitable treatment plan, especially when GCIPLT is thinning with no change in visual field performance.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی پایایی و تکرار پذیری دستگاه Spectral domain optical coherence tomography در اندازه گیری ضخامت ماکولا در چشمهای طبیعی قبل و بعد از گشاد کردن مردمک

Background: optical coherence tomography is one of the most valuable imaging techniques in the evaluation of macula. Objective: to investigate the repeatability and reproducibility of OCT  in measuring the macular thickness in normal eyes before and after pupil dilation. Methods: A total of 44 eyes were enrolled. All subjects underwent macular thickness measurement using the Cirrus SD-OCT ma...

متن کامل

Retinal Ganglion Cell Complex in Alzheimer Disease: Comparing Ganglion Cell Complex and Central Macular Thickness in Alzheimer Disease and Healthy Subjects Using Spectral Domain-Optical Coherence Tomography

Introduction: Alzheimer disease (AD) is the most common form of dementia worldwide. The modalities to diagnose AD are generally expensive and limited. Both the central nervous system (CNS) and the retina are derived from the cranial neural crest; therefore, changes in retinal layers may reflect changes in the CNS tissue. Optical coherence tomography (OCT) machine can show delicate retinal layer...

متن کامل

Comparison of Macular Thickness in Diabetic Macular Edema Using Spectral-Domain Optical Coherence Tomography and Time-Domain Optical Coherence Tomography

Purpose. To compare the macular thicknesses in diabetic macular edema (DME) measured with spectral-domain optical coherence tomography (SD-OCT) and time-domain (TD) OCT. Patients and Methods. The average macular thicknesses of 50 eyes of 29 patients with DME were measured using SD-OCT and TD-OCT. Results. The mean macular thicknesses measured with TD-OCT and SD-OCT were 401.5 ± 117.8 μm (mean ±...

متن کامل

Comparing Macular Thickness Measurements in Patients with Diabetic Macular Edema with the Optos Spectral OCT/SLO and Heidelberg Spectralis HRA + OCT

The aim of this study was to compare measurements of macular thickness, obtained from patients with diabetic macular edema, using two spectral-domain optical coherence tomography (SD-OCT) devices. These were the Spectralis Heidelberg Retina Angiograph + Optical Coherence Tomography (HRA + OCT) (Heidelberg Engineering), which is often considered the gold-standard for OCT measurement, and the Spe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017