Fracture Resistance of Composite Fixed Partial Dentures Reinforced with Pre-impregnated and Non-impregnated Fibers

نویسندگان

  • Ramin Mosharraf
  • Sepideh Torkan
چکیده

BACKGROUND AND AIMS The mechanical properties of fiber-reinforced composite fixed partial dentures (FPDs) are af-fected by fiber impregnation. The aim of this in vitro study was to compare the fracture resistance of composite fixed partialdentures reinforced with pre-impregnated and non-impregnated fibers. MATERIALS AND METHODS Groups (n=5) of three-unit fiber-reinforced composite FPDs (23 mm in length) from maxillary second premolar to maxillary second molar were fabricated on two abutments with pontic width of 12 mm. One group was fabricated as the control group with composite (Gradia) and the other two groups were fabricated with composite (Gradia) reinforced with pre-impregnated fiber (Fibrex ribbon) and non-impregnated fiber (Fiber braid), respectively. The specimens were stored in distilled water for one week at 37°C and then tested in a universal testing machine by means of a three-point bending test. Statistical analysis consisted of one-way ANOVA and a post hoc Scheffé's test for the test groups (α=0.05). RESULTS Fracture resistance (N) differed significantly between the control group and the other two groups (P<0.001), but there were no statistically significant differences between the pre-impregnated and non-impregnated groups (P=0.565). The degree of deflection measured (mm) did not differ significantly between the three groups (P=0.397), yet the mean deflection measured in pre-impregnated group was twice as that in the other two groups. CONCLUSION Reinforcement of composite with fiber might considerably increase the fracture resistance of FPDs; how-ever, the type of the fiber used resulted in no significant difference in fracture resistance of FPD specimens.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fiber-reinforced composite fixed partial denture to restore missing posterior teeth: a case report.

In patients refusing implant surgery for psychological reasons, when minimal tooth reduction is desired, a fiber-reinforced composite inlay fixed partial denture (IFPD) can be used to replace missing teeth. In comparison to other restorative systems this conservative approach carries a lower risk of pulp exposure and/or periodontal inflammation, maintaining the health of supporting tissues. The...

متن کامل

Bonded Orthodontic Retainer and Fixed Partial Denture Made with Fiber Reinforced Composite Resin

Retention is the phase of orthodontic treatment which maintains teeth in their orthodontically corrected positions, following the cessation of active orthodontic tooth movement. Development of resin-impregnated, fiber-reinforced composite materials has provided the potential to develop new approaches for stabilizing teeth and replacing teeth conservatively. This case report describes the rehabi...

متن کامل

In Vitro Study of Transverse Strength of Fiber Reinforced Composites

OBJECTIVE Reinforcement with fiber is an effective method for considerable improvement in flexural properties of indirect composite resin restorations. The aim of this in-vitro study was to compare the transverse strength of composite resin bars reinforced with pre-impregnated and non-impregnated fibers. MATERIALS AND METHODS Thirty six bar type composite resin specimens (3×2×25 mm) were cons...

متن کامل

اثر تعداد لایه‌های فایبر بر مقاومت به شکست بریج‌های کامپوزیتی تقویت شده با فایبر

Introduction: The purpose of this in vitro study was to introduce the fiber reinforced composite bridges and evaluate the most suitable site and position for placement of fibers in order to get maximum strength. Methods: The study included 20 second premolars and 20 second molars selected for fabricating twenty fiber reinforced composite bridges. Twenty specimens were selected for one fiber la...

متن کامل

Five-year survival of 3-unit fiber-reinforced composite fixed partial dentures in the anterior area.

OBJECTIVES The purpose of this clinical study was to evaluate the long-term outcome of 3-unit anterior fixed partial dentures (FPDs) made of fiber-reinforced resin composite (FRC), and to identify design factors influencing the survival rate. METHODS 52 patients (26 females, 26 males) received 60 indirectly made FRC FPDs, using pre-impregnated unidirectional glass fibers, requiring manual wet...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2012