A novel two-enzyme amperometric electrode for lactose determination.

نویسندگان

  • Handan Gülce
  • Ahmet Gülce
  • Attila Yildiz
چکیده

Coimmobilization of beta-galactosidase and glucose oxidase in a redox polymer, polyvinylferrocenium perchlorate (PVF+ ClO4-), led to the development of an enzyme electrode for the determination of lactose. The amperometric response of the electrode was measured at +0.70 V vs. SCE, which was due to the electrooxidation of enzymatically produced H2O2. The effects of the substrate and buffer concentrations as well as the pH on the electrode response were elucidated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flow-Injection Amperometric Determination of Ascorbic Acid Using a Graphite-Epoxy Composite Electrode Modified with Cobalt Phthalocyanine

A flow injection method is reported for the determination of ascorbic acid based on amperometric detection, using a cobalt(II) phthalocyanine (CoPc) modified graphite-epoxy electrode. The amperometric respons was evaluated with regard to pH, ionic strength of the electrolyte, flow rate of the carrier solution, injected sample volume and conditioning time of the electrode. The limit of detec...

متن کامل

DETERMINATION OF AMOXYCYLLIN AND CLAVULANIC ACID IN PHARMACEUTICAL DOSAGE FORMS BY HPLC WITH AMPEROMETRIC DETECTION

A simple and sensitive high performance liquid chromatographic method with electrochemical detection is described for the quantitative determination of the amoxycillin and clavulanic acid in pharmaceutical dosage forms. Separation of sample components occurs on a reversed phase C18 column with a mobile phase consisting of methanol-water-phosphate buffer. For the amperometric detection, the pote...

متن کامل

A disposable, screen-printed electrode for the amperometric determination of azide based on the immobilization with catalase or tyrosinase.

A disposable, screen-printed electrode based on the immobilization of catalase or tyrosinase was developed to construct biosensors for the amperometric determination of azide. The determination principles for azide by these two methods are based on inhibiting the enzymatic consumption of an electrode-detectable substance (hydrogen peroxide or catechol) on an enzyme-immobilized electrode. Both o...

متن کامل

Flow injection amperometric enzyme biosensor for direct determination of organophosphate nerve agents.

A flow injection amperometric biosensor for the determination of organophosphate nerve agents was developed. The biosensor incorporated an immobilized enzyme reactor that contains the enzyme organophosphorus hydrolase covalently immobilized on activated aminopropyl controlled pore glass beads and an electrochemical flow-through detector containing carbon paste working electrode, a silver/silver...

متن کامل

Design and Optimization of a New Voltammetric Method for Determination of Isoniazid by Using PEDOT Modified Gold Electrode in Pharmaceuticals

Isoniazid (INH) was studied with regard to its electrochemical treatment on a strongly alkaline solution of a poly (3,4-ethylenedioxythiophene)-modified gold electrode, using both cyclic voltammetry and controlled potential techniques. This composite electrode exhibited 4-fold higher oxidation of INH, in accordance with peak densities, than the bare gold electrode. It was used the central compo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 18 2  شماره 

صفحات  -

تاریخ انتشار 2002