We evaluated three commercially available methods for determining lipase (EC 3.1.1.3) in serum--the Du Pont aca, Boehringer Mannheim Diagnostics (BMD), and Kodak Ektachem (EK) procedures--for their analytical properties and diagnostic efficiencies. Titrimetry was used as the comparative method. The BMD and EK methods showed better agreement with the titrimetric method, owing to the presence of the necessary cofactor, colipase, in their reagents. Colipase also increased the analytical sensitivity of the BMD and EK procedures as compared with the aca method. Determinations of serum lipase, by all methods, had a clinical sensitivity in excess of 80% for acute pancreatitis; the specificity of the lipase test was about 60%, or twice that of serum amylase. Serum lipase determinations with the current, simpler technology are superior to total amylase in the diagnosis of patients with acute pancreatitis. When a colipase-supplemented method is used, a serum lipase value greater than 10-fold the upper reference limit appears to be pathognomonic for acute pancreatitis or inflammation of organs close to the pancreas.
منابع مشابه
Accuracy in clinical chemistry--does anybody care?
The role of clinical chemistry in the diagnostic process has been enhanced by the evolution of better instrumentation and analytical techniques. The quality of some laboratory tests, however, has not kept pace with these advances. I present three examples--serum iron, serum lipase, and nonisotopic immunoassays--assays where some currently used methodologies are highly flawed. Causes for the les...
متن کاملMeasuring carboxypeptidase A activity with a centrifugal analyzer: analytical and clinical considerations.
This adaptation of a commercially available kit for automated measurement of carboxypeptidase A (CPA; EC 3.4.17.1) activity in serum with the Cobas Bio centrifugal analyzer extends the linear range to an activity concentration of 82 U/L. Results obtained by the described method correlated closely (r = 0.98) with those by the manual kit method. The reference interval for 150 apparently normal in...
متن کاملTwo automated fully enzymatic assays for lipase activity in serum compared: positive interference from post-heparin lipase activity.
The fully enzymatic Wako and Ektachem assays for pancreatic lipase in serum were found to yield precise (especially Ektachem) and consistent results that were significantly correlated (r = 0.995). Less good concordance was found with the turbidimetric aca method, results being on several occasions above normal by Wako or Ektachem but within the reference limit by the aca. Supplementation of aca...
متن کاملFluorometric serum lipase assay: evaluation of monodecanoyl fluorescein as substrate.
The elements of the mechanized fluorometric lipase (EC 3.1.1.3) assay of Fleisher and Schwartz [Clin. Chem. 17, 417 (1971)] were made optimum; a manual adaptation was also developed. Hydrolysis of the monodecanoyl fluorescein substrate by hog pancreatic lipase is a zero-order reaction. The hydrolytic activity of normal human serum, serum from hospitalized patients without pancreatitis, and seru...
متن کاملAssociation between Lipoprotein Lipase Hind III Polymorphism and Serum Levels of Lipids in Semnan City
Background & Aims: Lipoprotein lipase (LPL) is one of the key enzymes regulating the metabolism of triglycerides (TG) and HDL cholesterol. The lipoprotein lipase (LPL) gene polymorphisms are possibly involved in the pathophysiology of dyslipidemia. Hind III polymorphism is one of the most common polymorphisms in LPL gene. In some studies, association of Hind III polymorphism with dyslipidemia h...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 32 7 شماره
صفحات -
تاریخ انتشار 1986