A low-volume, low-pressure tracheal tube cuff reduces pulmonary aspiration.

نویسندگان

  • Peter J Young
  • Sivarajasingham Pakeerathan
  • Mark C Blunt
  • Sriharsha Subramanya
چکیده

OBJECTIVE Leakage of fluid from the subglottic space to the lungs occurs along the longitudinal folds within the wall of an inflated high-volume, low-pressure (HVLP) cuff. The low-volume, low-pressure (LVLP) cuff does not have these folds yet allows for convenient and reliable control of tracheal wall pressure. Pulmonary aspiration during anesthesia has been linked with postoperative pneumonia and during critical illness causes ventilator-associated pneumonia. DESIGN Prospective, blinded, randomized controlled trial; prospective observational study; and benchtop models. SETTING Department of Anaesthesia and Critical Care, Queen Elizabeth Hospital. PATIENTS Anesthetized patients (n=38) and critically ill patients with either an LVLP or HVLP cuffed tracheostomy tube following swallow assessments (n=67). INTERVENTIONS The LVLP cuff was compared with HVLP cuffs for leakage of dye placed in the subglottic space to the tracheobronchial tree in a rigid tracheal model and a benchtop pig trachea model (before and after a standardized cuff movement). MEASUREMENTS AND MAIN RESULTS In the rigid tracheal model, the incidence of leakage was 0% in the LVLP group and 100% in the HVLP group (p<.01). Dye leakage in the pig tracheal model with HVLP cuffs was 44% before tube movement, increasing to 79% afterward. The LVLP cuff did not leak in the pig tracheal model. Dye leakage in anesthetized patients was 0% before movement and 5% after in the LVLP group and in the HVLP group 22% increasing to 67% after movement (p<.001). Forty-nine percent of swallow assessments were scored as failed in the critical care patients with HVLP tracheostomy tube cuffs, and there were no episodes of aspiration following swallow assessment in the LVLP group (p<.05). CONCLUSIONS The LVLP cuffed tracheal and tracheostomy tubes reduced pulmonary aspiration in the benchtop models and in anesthetized and critically ill patients. The single failure of the LVLP cuff in the anesthesia group was probably associated with accidental endobronchial intubation following tube movement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of tracheal tube cuff inflation pressure among anesthesia team with different gradual level

Background & Objectives: Tracheal intubation is frequently performed in operating room. Over inflation of the endotracheal tube cuff is a risk factor for tracheal ischemia and subsequent complications. On the other hand inadequate cuff pressure increases the risk of aspiration of gastric contents. In this study, the endotracheal tube cuff pressure filled by the anesthesia team has been compared...

متن کامل

Gel lubrication of the tracheal tube cuff reduces pulmonary aspiration.

BACKGROUND Leakage of fluid occurs along the longitudinal folds within the wall of an inflated high-volume, low-pressure cuff. Theoretically, lubrication of the cuff with a water-soluble gel might prevent aspiration by plugging the channels in the cuff wall. Pulmonary aspiration during anesthesia has been linked with postoperative pneumonia and during critical illness causes ventilator-associat...

متن کامل

Wren, Boyle, and the origins of intravenous injections and the Royal Society of London.

impact on VAP. Second, we disagree with the opinion that the orientation of the endotracheal tube below horizontal will result in reduced incidence of VAP for the reason that it is based on insufficient clinical data: three experimental animal (sheep) studies, a randomized controlled trial with 60 ventilated infants that compared the tracheal colonization rate and not the VAP incidence in supin...

متن کامل

Tracheal Rupture due to Diffusion of Nitrous Oxide to Cuff of High-Volume, Low-Pressure Intubation Tube.

Tracheal rupture is a rare complication of endotracheal intubation. Risk factors include short neck, repeated attempts due to failed intubation, inappropriate stylus, over-inflation of the cuff, poor positioning of the tube, inappropriate tube size, weakened membrane structure due to steroid use, chronic obstructive pulmonary disease, tracheomalacia, kyphosis, and use of nitric oxide during the...

متن کامل

The tracheal tube: gateway to ventilator-associated pneumonia

Ventilator-associated pneumonia (VAP) is a major healthcare-associated complication with considerable attributable morbidity, mortality and cost. Inherent design flaws in the standard high-volume low-pressure cuffed tracheal tubes form a major part of the pathogenic mechanism causing VAP. The formation of folds in the inflated cuff leads to microaspiration of pooled oropharyngeal secretions int...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Critical care medicine

دوره 34 3  شماره 

صفحات  -

تاریخ انتشار 2006