Cadence Feedback With ECE PEDO to Monitor Physical Activity Intensity

نویسندگان

  • Fusun Ardic
  • Esra Göcer
چکیده

The purpose of this study was to examine the monitoring capabilities of the equipment for clever exercise pedometer (ECE PEDO) that provides audible feedback when the person exceeds the upper and lower limits of the target step numbers per minute and to compare step counts with Yamax SW-200 (YX200) as the criterion pedometer.A total of 30 adult volunteers (15 males and 15 females) were classified as normal weight (n = 10), overweight (n = 10), and obese (n = 10). After the submaximal exercise test on a treadmill, the moderate intensity for walking was determined by using YX200 pedometer and then the number of steps taken in a minute was measured. Lower and upper limits of steps per minute (cadence) were recorded in ECE PEDO providing audible feedback when the person's walking speed gets out of the limits. Volunteers walked for 30 minutes in the individual step count range by attaching the ECE PEDO and YX200 pedometer on both sides of the waist belt in the same session. Step counts of the volunteers were recorded. Wilcoxon, Spearman correlation, and Bland-Altman analyses were performed to show the relationship and agreement between the results of 2 devices.Subjects took an average of 3511 ± 426 and 3493 ± 399 steps during 30 minutes with ECE PEDO and criterion pedometer, respectively. About 3500 steps taken by ECE PEDO reflected that this pedometer has capability of identifying steps per minute to meet moderate intensity of physical activity. There was a strong correlation between step counts of both devices (P < 0.001, r = 0.96). Correlations across all three BMI categories and both sex remained consistently high ranging from 0.92 to 0.95. There was a high level of agreement between the ECE PEDO and YX200 pedometer in the Bland-Altman analysis.Although both devices showed a strong similarity in counting steps, the ECE PEDO provides monitoring of intensity such that a person can walk in a specified time with a desired speed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Walking Cadence to Exercise at Moderate Intensity for Adults: A Systematic Review

Background. Most adults choose walking as a leisure activity. However, many do not reach the international physical activity guidelines for adults, which recommend moderate intensity aerobic activity for at least 150 minutes/week in bouts of 10 minutes. Purpose. This systematic review provides an update on the walking cadence required to reach moderate intensity in adults and older adults, iden...

متن کامل

Pilot study: can older inactive adults learn how to reach the required intensity of physical activity guideline?

Most individuals do not reach the recommended physical activity level of at least 150 minutes of aerobic exercise (AE) at moderate-to-vigorous intensity per week. For example, only 13% of older Canadian adults reach World Health Organization physical activity guideline (PAG). One of the reasons might be a difficulty identifying the required intensity. Twenty-five inactive older adults received ...

متن کامل

Activity-monitor accuracy in measuring step number and cadence in community-dwelling older adults.

The primary purpose of this study was to investigate the accuracy of the activPAL physical activity monitor in measuring step number and cadence in older adults. Two pedometers (New-Lifestyles Digi-Walker SW-200 and New-Lifestyles NL2000) used in clinical practice to count steps were simultaneously evaluated. Observation was the criterion measure. Twenty-one participants (65-87 yr old) recruite...

متن کامل

Total energy expenditure estimated using foot-ground contact pedometry.

Routine walking and running, by increasing daily total energy expenditure (TEE), can play a significant role in reducing the likelihood of obesity. The objective of this field study was to compare TEE estimated using foot-ground contact time (Tc)-pedometry (TEE(PEDO)) with that measured by the criterion doubly labeled water (DLW) method. Eight male U.S. Marine test volunteers [27 +/- 4 years of...

متن کامل

A steps/minute value for moderate intensity physical activity in adolescent females.

The number of steps/minute (i.e., cadence) that equates to moderate intensity in adolescents is not known. To that end, 31 adolescent females walked on a treadmill at 5 different speeds while wearing an ActivPAL accelerometer and oxygen uptake was recorded by indirect calorimetry. The relationship between metabolic equivalents (METs) and cadence was explored using 3 different analytical approac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 95  شماره 

صفحات  -

تاریخ انتشار 2016