Effect of glutaraldehyde fixation and valve constraint conditions on porcine aortic valve leaflet coaptation.
نویسندگان
چکیده
In an investigation of the influence of glutaraldehyde fixation pressure and subsequent valve constraint on the coaptive characteristics of porcine aortic valves, 14 valves were examined, eight having been fixed at low pressure (congruent to 1 mm Hg) and six at high pressure (80 mm Hg). The coaptive ratios of the left and right coronary leaflets in the low-pressure-fixed valves showed a significant improvement over those of the same leaflets in the high-pressure-fixed valves. Inflation to 80 mm Hg results in a variable "peeling back" of the coaptive margins of the low-pressure-fixed valves but not of the high-pressure-fixed valves. Comparable coaptive ratios are therefore expected during full inflation of the unconstrained valves fixed both at low pressure and at high pressure. Constraining the low-pressure-fixed valves during inflation to simulate the effect of mounting on a rigid stent produced either a reduction or virtual elimination of this "peeling back" motion or in some instances a slight reversal of the effect, thus increasing the width of the coaptive margin. Hence it is expected that the stented low-pressure-fixed valve will manifest better coaptation than the high-pressure-fixed valve. Finally, the experimental findings of this study, combined with the improved mechanical function of the leaflet tissue already known to occur in the low-pressure-treated valves, provide a convincing case for valve fixation to be carried out under lower pressures.
منابع مشابه
Collagen Bundle Orientation Explains Aortic Valve Leaflet Coaptation
The aortic valve owes its strength and durability to a network of collagen fibers within the leaflets. However, the pattern of these fibers and their role in valve function is not well understood. We imaged and quantified the macroscopically visible pattern of collagen fibers in seven porcine aortic valves with particular attention to measuring this pattern in the unstrained leaflet. We then us...
متن کاملInfluence of fixation conditions on the performance of glutaraldehyde-treated porcine aortic valves: towards a more scientific basis.
To maintain optimum mechanical properties in glutaraldehyde-treated heart-valve tissue the full collagen crimp geometry originally present in the relaxed fresh tissue should be retained. By varying the pressure at which glutaraldehyde fixation is carried out, considerable alterations to this crimp geometry can be achieved. The mechanical stiffness of the preserved tissue is consequently affecte...
متن کاملA Fluid Structure Interaction Model of Native Aortic Valve with Physiologic Blood Pressure and Tissue Properties
The kinematics and dynamics of the aortic valve (AV) are highly dependent on the combined mechanical properties of the valve and the aortic root (AR), as well as the blood flow. Previous numerical models of physiological AV and AR, that included coaptation under the full cardiac cycle, ignored the influence of the blood flow (performing “dry” simulations). This study presents a full fluid-struc...
متن کاملStraightening of curved pattern of collagen fibers under load controls aortic valve shape.
The network of collagen fibers in the aortic valve leaflet is believed to play an important role in the strength and durability of the valve. However, in addition to its stress-bearing role, such a fiber network has the potential to produce functionally important shape changes in the closed valve under pressure load. We measured the average pattern of the collagen network in porcine aortic valv...
متن کاملElastic and viscoelastic material behaviour of fresh and glutaraldehyde-treated porcine aortic valve tissue.
In order to obtain better insight into the changes in material properties of aortic valve tissue due to the treatment with glutaraldehyde, comparative tensile and relaxation experiments have been performed with strips taken from porcine aortic valve tissue in a fresh condition and after the treatment. To eliminate biological deviations between different strips, the comparative experiments were ...