Patient specific quality assurance for the delivery of intensity modulated radiotherapy
نویسندگان
چکیده
A patient specific quality assurance program has been developed to facilitate the clinical implementation of intensity modulated radiotherapy (IMRT) delivered using a micro-multileaf collimator. The methodology includes several dosimetric tasks that are performed prior to the treatment of each patient. Film dosimetry is performed for each individual field and for the multifield composite plan. Individual field measurements are performed at a depth of 5 cm in a water equivalent slab phantom; export of dose calculations from the treatment planning system is similarly specified. For the composite distribution, parameters from the patient plan are applied to an IMRT phantom, and film is exposed in an axial orientation. Distributions are compared with the aid of software developed for the specific tasks. The measured and calculated dose distributions can be superimposed and positioned graphically using move, rotate, and mirror tools, as well as by specifying isocenter coordinates and using fiducial marks. Horizontal and vertical profiles are available for analysis. Dose difference, distance-to-agreement, and gamma index, the minimum scaled multidimensional distance between a measurement and a calculation point determined in combined dose and physical distance space, are calculated along a specified isodose line and displayed. gamma provides an excellent measure of disagreement between measurement and calculation for complex intensity distributions. We specify 3% dose difference and 3 mm distance as our scaling acceptability criteria. Absolute dosimetry for each composite plan is performed using an ionization chamber. To date, excellent agreement between measurements and calculations has been observed.
منابع مشابه
Dosimetric Study of an Indigenous and Heterogeneous Pelvic Phantom for Radiotherapy Quality Assurance
Introduction: In vitro dosimetric verification prior to patient treatment plays a key role in accurate and precision radiotherapy treatment delivery. Since the human body is a heterogeneous medium, the aim of this study was to design a heterogeneous pelvic phantom for radiotherapy quality assurance. Material and Methods: A pelvic phantom was ...
متن کاملA Specific Patient Quality Assurance (PSQA) procedure for a Co-60 source based High Dose Rate Brachytherapy
Introduction: In radiation therapy, accurate dose determination and precise dose delivery to the tumor are directly associated with better treatment outcomes in terms of higher tumor control and lower post radiation therapy complications. The current study aims the development and clinical application of the Patient Specific Quality Assurance (PSQA) procedures for nasopharyngea...
متن کاملDosimetry for audit and clinical trials: challenges and requirements
Many important dosimetry audit networks for radiotherapy have their roots in clinical trial quality assurance (QA). In both scenarios it is essential to test two issues: does the treatment plan conform with the clinical requirements and is the plan a reasonable representation of what is actually delivered to a patient throughout their course of treatment. Part of a sound quality program would b...
متن کاملFeasibility of a 3D-printed anthropomorphic patient-specific head phantom for patient-specific quality assurance of intensity-modulated radiotherapy
This study evaluated the feasibility of utilizing a 3D-printed anthropomorphic patient-specific head phantom for patient-specific quality assurance (QA) in intensity-modulated radiotherapy (IMRT). Contoured left and right head phantoms were converted from DICOM to STL format. Fused deposition modeling (FDM) was used to construct an anthropomorphic patient-specific head phantom with a 3D printer...
متن کاملFewer beams and segments result in a shorter delivery time and a better quality intensity-modulated radiotherapy plan in gastric cancer
Background: This study evaluated whether IMRT using fewer beams and segments could reduce delivery time without compromising plan quality in gastric cancer adjuvant radiotherapy. Materials and Methods: Fifteen patients with advanced gastric cancer who underwent D2, R0 surgery were included in this study. IMRT plans for each patient were designed as 7 equal beams with 40 segments, 5 beams with 2...
متن کامل