High-speed spectral-domain optical coherence tomography at 1.3 mum wavelength.
نویسندگان
چکیده
We demonstrate a high-speed spectral domain optical coherence tomography (SD-OCT) system capable of acquiring individual axial scans in 24.4 micros at a rate of 19,000 axial scans per second, using an InGaAs line scan camera and broadband light source centered at 1.31microm. Sensitivity of >105 dB over a 2-mm depth range was obtained with a free-space axial resolution of 12-14 microm, in agreement with our signal-to-noise ratio predictions. Images of human tissue obtained in vivo with SD-OCT show similar penetration depths to those obtained with state-of-the-art time domain OCT despite the ten-fold higher image acquisition speed. These results demonstrate the potential of 1.3 microm SD-OCT for high-speed and high-sensitivity imaging in patients.
منابع مشابه
Long-wavelength optical coherence tomography at 1.7 microm for enhanced imaging depth.
Multiple scattering in a sample presents a significant limitation to achieve meaningful structural information at deeper penetration depths in optical coherence tomography (OCT). Previous studies suggest that the spectral region around 1.7 microm may exhibit reduced scattering coefficients in biological tissues compared to the widely used wavelengths around 1.3 mum. To investigate this long-wav...
متن کاملFull-field time-encoded frequency-domain optical coherence tomography.
Ultrahigh axial resolution surface profiling as well as volumetric optical imaging based on time encoded optical coherence tomography in the frequency domain without any mechanical scanning element is presented. A frequency tuned broad bandwidth titanium sapphire laser is interfaced to an optical microscope (Axioskop 2 MAT, Carl Zeiss Meditec) that is enhanced with an interferometric imaging he...
متن کاملSpectral domain optical coherence tomography: ultra-high speed, ultra-high resolution ophthalmic imaging.
OBJECTIVE To introduce a new ophthalmic optical coherence tomography technology that allows unprecedented simultaneous ultra-high speed and ultra-high resolution. METHODS Using a superluminescent diode source, a clinically viable ultra-high speed, ultra-high resolution spectral domain optical coherence tomography system was developed. RESULTS In vivo images of the retina, the optic nerve he...
متن کاملHigh-speed three-dimensional human retinal imaging by line-field spectral domain optical coherence tomography.
Line-field spectral domain optical coherence tomography (LF-SDOCT) has been developed for very high-speed three-dimensional (3D) retinal imaging. By this technique, the A-line rate significantly improved to 823,200 A-lines/s for single frame imaging and 51,500 A-lines/s for continues frame imaging. The frame rate at continues frame imaging is 201 fps. This 3D acquisition speed is more than two ...
متن کاملPulsed-source and swept-source spectral-domain optical coherence tomography with reduced motion artifacts.
Significant motion artifacts may arise in conventional spectral-domain optical coherence tomography due to sample or probe motion during the exposure time of a CCD array. We show, for the first time to our knowledge, that the motion artifacts can be greatly reduced by short illumination of individual CCD pixels and that this can be accomplished by use of two distinct classes of light sources: b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Optics express
دوره 11 26 شماره
صفحات -
تاریخ انتشار 2003