Adaptation requirements due to anatomical changes in free-breathing and deep-inspiration breath-hold for standard and dose-escalated radiotherapy of lung cancer patients.

نویسندگان

  • Patrik Sibolt
  • Wiviann Ottosson
  • David Sjöström
  • Christina Larsen
  • Claus F Behrens
چکیده

BACKGROUND Radiotherapy of lung cancer patients is subject to uncertainties related to heterogeneities, anatomical changes and breathing motion. Use of deep-inspiration breath-hold (DIBH) can reduce the treated volume, potentially enabling dose-escalated (DE) treatments. This study was designed to investigate the need for adaptation due to anatomical changes, for both standard (ST) and DE plans in free-breathing (FB) and DIBH. MATERIAL AND METHODS The effect of tumor shrinkage (TS), pleural effusion (PE) and atelectasis was investigated for patients and for a CIRS thorax phantom. Sixteen patients were computed tomography (CT) imaged both in FB and DIBH. Anatomical changes were simulated by CT information editing and re-calculations, of both ST and DE plans, in the treatment planning system. PE was systematically simulated by adding fluid in the dorsal region of the lung and TS by reduction of the tumor volume. RESULTS Phantom simulations resulted in maximum deviations in mean dose to the GTV-T (GTV-T) of -1% for 3 cm PE and centrally located tumor, and + 3% for TS from 5 cm to 1 cm diameter for an anterior tumor location. For the majority of the patients, simulated PE resulted in a decreasing GTV-T with increasing amount of fluid and increasing GTV-T for decreasing tumor volume. Maximum change in GTV-T of -3% (3 cm PE in FB for both ST and DE plans) and + 10% (2 cm TS in FB for DE plan) was observed. Large atelectasis reduction increased the GTV-T with 2% for FB and had no effect for DIBH. CONCLUSION Phantom simulations provided potential adaptation action levels for PE and TS. For the more complex patient geometry, individual assessment of the dosimetric impact is recommended for both ST and DE plans in DIBH as well as in FB. However, DIBH was found to be superior over FB for DE plans, regarding robustness of GTV-T to TS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparative Study of 3-D Conformal Radiotherapy Treatment Plans with and Without Deep Inspiration Breath-Hold Technique for Left-Sided Breast Cancer

Introduction: The rate of cardiac diseases have increased among patients who underwent radiotherapy for left-sided breast cancer. The study’s aim was evaluate the dose to organs at risk in free-breathing 3-dimensional conformal (FB-3DCRT) against 3-dimensional conformal deep inspiration breath-hold (3DCRT-DIBH) in patients with left-sided breast cancer. Ma...

متن کامل

Dosimetric and clinical advantages of deep inspiration breath-hold (DIBH) during radiotherapy of breast cancer

BACKGROUND To investigate the potential dosimetric and clinical benefits of Deep Inspiration Breath-Hold (DIBH) technique during radiotherapy of breast cancer compared with Free Breathing (FB). METHODS Eight left-sided breast cancer patients underwent a supervised breath hold during treatment. For each patient, two CT scans were acquired with and without breath hold, and virtual simulation wa...

متن کامل

Cardiac dose reduction with breathing adapted radiotherapy using self respiration monitoring system for left-sided breast cancer

PURPOSE To quantify the cardiac dose reduction during breathing adapted radiotherapy using Real-time Position Management (RPM) system in the treatment of left-sided breast cancer. MATERIALS AND METHODS Twenty-two patients with left-sided breast cancer underwent CT scans during breathing maneuvers including free breathing (FB), deep inspiration breath-hold (DIBH), and end inspiration breath-ho...

متن کامل

The Role of Active Breathing Control-Moderate Deep Inspiration Breath-Hold (ABC-mDIBH) Usage in non-Mastectomized Left-sided Breast Cancer Radiotherapy: A Dosimetric Evaluation

The aim of this study is to evaluate the dosimetric impact of utilizing Active Breathing Control-moderate deep inspiration breath-hold (ABC-mDIBH) technique in early-stage left-sided breast cancer radiotherapy (RT). Twenty-five patients with left-sided early-stage breast cancer undergoing breast-conserving surgery referred to our department for adjuvant radiotherapy between October 2010 and Oct...

متن کامل

Challenges of maintaining breath-hold conformity for breast patients while using the deep inspiration breath-hold technique

Deep inspiration breath-hold (DIBH) is used for whole breast radiotherapy, as a means of providing better dose homogeneity. This can be achieved by lower doses to the organs at risk, less patient movement and better set up. Most patients offered DIBH treatment are left-sided breast cancer, or ductal carcinoma in situ (DCIS) patients, due to the proximity of the heart to the chest wall so it is ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta oncologica

دوره 54 9  شماره 

صفحات  -