How to Adapt the Implantation Technique for the New SAPIEN 3 Transcatheter Heart Valve Design

نویسندگان

  • Gerhard Schymik
  • Holger Schröfel
  • Martin Heimeshoff
  • Armin Luik
  • Martin Thoenes
  • Lazar Mandinov
چکیده

The new balloon-expandable Edwards SAPIEN 3 THV has significant design improvements requiring adjustments in the implantation technique as compared to the previous generation SAPIEN XT. Basically, the new valve requires less oversizing due to the outer skirt, which, if positioned underneath the annulus, can reduce the occurrence and severity of paravalvular leak (PVL). As with any transcatheter vale, a thorough assessment of the device-landing-zone, the surrounding structures, and the distribution of calcifications is of vast importance. Once the SAPIEN 3 valve is positioned with the initial orientation of the middle balloon marker at the level of the leaflet hinge points, the outer skirt will remain under the annulus, despite the foreshortening of the lower inflow portion of the valve. If there is an incomplete apposition, the outer skirt can conform to the anatomy, close the gaps, and reduce the risk of PVL. When calcifications are located on the edges of the annulus, PVL is common with the SAPIEN XT THV but dramatically reduced with the SAPIEN 3 THV. If the calcification extends from the annulus into the entire LVOT, there is always an incomplete apposition of the either valve frame; however, the resulting PVL is reduced by the outer skirt of the SAPIEN 3. In 165 consecutive SAPIEN 3 patients, 89.7% (n = 145) had none or a trace PVL and there were no patients with moderate or severe PVL. The new generation SAPIEN 3 valve allows more challenging anatomies to be treated, requires less oversizing, and can reduce PVL.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Predictors of Permanent Pacemaker Implantations and New-Onset Conduction Abnormalities With the SAPIEN 3 Balloon-Expandable Transcatheter Heart Valve.

OBJECTIVES This study investigates the influence of implantation depth and prosthesis oversizing on conduction abnormalities (CA) and permanent pacemaker implantation (PPI) after SAPIEN 3 (Edwards Lifesciences, Irvine, California) implantation. BACKGROUND CA and PPIs are frequent complications after transcatheter aortic valve replacement with a next-generation balloon-expandable transcatheter...

متن کامل

Procedural Results and Clinical Outcomes of Transcatheter Aortic Valve Implantation in Switzerland: An Observational Cohort Study of Sapien 3 Versus Sapien XT Transcatheter Heart Valves.

BACKGROUND New generation transcatheter heart valves (THV) may improve clinical outcomes of transcatheter aortic valve implantation. METHODS AND RESULTS In a nationwide, prospective, multicenter cohort study (Swiss Transcatheter Aortic Valve Implantation Registry, NCT01368250), outcomes of consecutive transfemoral transcatheter aortic valve implantation patients treated with the Sapien 3 THV ...

متن کامل

Transcatheter Heart Valve Selection and Permanent Pacemaker Implantation in Patients With Pre‐Existent Right Bundle Branch Block

BACKGROUND Right bundle branch block is an established predictor for new conduction disturbances and need for a permanent pacemaker (PPM) after transcatheter aortic valve replacement. The aim of the study was to evaluate the absolute rates of transcatheter aortic valve replacement related PPM implantations in patients with pre-existent right bundle branch block and categorize for different tran...

متن کامل

Comparison between the SAPIEN S3 and the SAPIEN XT transcatheter heart valves: A single-center experience

AIM To investigate the clinical outcomes of transcatheter aortic valve implantation (TAVI) with the SAPIEN 3 transcatheter heart valve (S3-THV) vs the SAPIEN XT valve (XT-THV). METHODS We retrospectively analyzed 507 patients that underwent TAVI with the XT-THV and 283 patients that received the S3-THV at our institution between March 2010 and December 2015. RESULTS Thirty-day mortality (3....

متن کامل

Repositionable Versus Balloon‐Expandable Devices for Transcatheter Aortic Valve Implantation in Patients With Aortic Stenosis

BACKGROUND The safety and effectiveness of the fully repositionable LOTUS valve system as compared with the balloon-expandable Edwards SAPIEN 3 prosthesis for the treatment of aortic stenosis has not been evaluated to date. METHODS AND RESULTS All patients undergoing transcatheter aortic valve implantation with the Edwards SAPIEN 3 or the LOTUS valve system were included into the Swiss Transc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 28  شماره 

صفحات  -

تاریخ انتشار 2015