Balloon occlusion of the carotid artery for the angiographic visualization of Blalock-Taussig shunts and pulmonary arteries.

نویسندگان

  • B Marino
  • S Giannico
  • L Pasquini
  • A Corno
  • S Picardo
چکیده

We describe the use of a balloon catheter to occlude the right or left carotid artery as a way of directing contrast material to the pulmonary arteries. This procedure was carried out in the postoperative study of 14 children who had undergone a Blalock-Taussig shunt. The method was reliable, and the angiograms provided excellent visualization of the pulmonary arteries using only small volumes of contrast material.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous Common Carotid Artery Access for Pediatric Interventional Cardiac Catheterization.

BACKGROUND Surgical cutdown for access to the common carotid artery provides a more direct route for certain pediatric cardiac interventions and avoids femoral artery injury in small infants. The safety of percutaneous carotid access (PCA) in children is unknown. METHODS AND RESULTS Retrospective review of PCA at Texas Children's Hospital and Children's Healthcare of Atlanta. From July 2006 t...

متن کامل

Transcatheter occlusion of a Blalock-Taussig shunt with a detachable balloon in a child.

A case of transcatheter occlusion of a Blalock-Taussig shunt with a detachable silicone filled balloon is described. This 11 year old boy had previously had a repair of tetralogy of Fallot together with ligation of a large Blalock-Taussig shunt. Though there was a good surgical result, the shunt proved to be incompletely closed leaving a significant left to right shunt. As an alternative to a f...

متن کامل

Blalock - Taussig shunt . modified ( polytetrafluoroethylene ) Balloon dilatation of a stenosed

A 17 month old girl with tricuspid atresia, ventricular septal defect, subvalvar and valvar pulmonary stenosis, and increasing cyanosis had angiographic evidence ofproximal stenosis of a right modified (5 mm diameter) Blalock-Taussig shunt. She underwent palliative balloon angioplasty with a 6 mm Schneider balloon catheter. Successful dilatation was achieved without complication. Four months la...

متن کامل

Recanalisation of an occluded modified Blalock-Taussig shunt by balloon dilatation.

A four year old boy with pulmonary atresia and ventricular septal defect had an acute cyanotic episode three years after undergoing a right-sided, 6 mm diameter, modified Blalock-Taussig shunt. On admission no continuous murmur could be heard from the shunt and the typical high velocity, continuous flow profile of the shunt could not be identified by Doppler echocardiography. At catheterisation...

متن کامل

Perigraft seroma complicating the modified Blalock-Taussig shunts: two consecutive instances with review of literature.

Systemic-to-pulmonary artery shunts using polytetrafluoroethylene (PTFE) (modified Blalock-Taussig shunt) are being used successfully in palliation of cyanotic congenital heart diseases. Graft thrombosis is by far the most common complication of the procedure. Persistant serum leakage through PTFE graft causing perigraft seroma is a rare but devastating complication resulting in increased durat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 94 2  شماره 

صفحات  -

تاریخ انتشار 1988