Improving the repeatability of topographic height measurements in confocal scanning laser imaging using maximum-likelihood deconvolution.
نویسندگان
چکیده
PURPOSE To evaluate maximum likelihood (ML) blind deconvolution as a technique for improving the repeatability of topographic height measurements obtained from scanning laser tomography (Heidelberg Retinal Tomograph [HRT]; Heidelberg Engineering, Heidelberg, Germany). METHODS ML blind deconvolution is an image-processing technique that estimates the original scene from a degraded image. This technique has been used in confocal scanning laser microscopy to remove "out-of-focus" haze in three-dimensional confocal image stacks. ML blind deconvolution requires no prior estimation of the point-spread function (PSF), as opposed to classic linear deconvolution methods. Instead, the algorithm estimates an initial PSF based on the optical setup of the confocal scanning device and optics of the eye and iteratively proceeds to a solution. The improvement in repeatability of height measurements from mean topography images within scan (intrascan) and between scans (interscan) afforded by ML deconvolution was evaluated in a test-retest series of HRT images from 40 ocular hypertensive and glaucomatous patients with varying degrees of media opacity. RESULTS There was an improvement in intrascan repeatability in 38 out of the 40 mean topography images (median improvement 2.5 microm, inter-quartile range 2.19, P < 0.001), and an improvement in interscan repeatability in 33 of the 40 mean topographies (median improvement, 1.0 microm, interquartile range 3.49, P < 0.001). There was a positive association between the magnitude of the improvement in repeatability and the level of mean pixel height standard deviation (MPHSD), intrascan (P = 0.004) and interscan (P = 0.002). CONCLUSIONS ML blind deconvolution algorithm improves the repeatability of topographic height measurements from the HRT. This improvement was greater in patients with poorer quality images.
منابع مشابه
Richardson-Lucy algorithm with total variation regularization for 3D confocal microscope deconvolution.
Confocal laser scanning microscopy is a powerful and popular technique for 3D imaging of biological specimens. Although confocal microscopy images are much sharper than standard epifluorescence ones, they are still degraded by residual out-of-focus light and by Poisson noise due to photon-limited detection. Several deconvolution methods have been proposed to reduce these degradations, including...
متن کاملOptic disc topographic parameters measured in the normal cynomolgus monkey by confocal scanning laser tomography.
AIM To study optic disc topographic parameters in normal cynomolgus monkeys by Heidelberg retina tomograph (HRT). METHODS 12 optic disc topographic parameters were investigated in 36 normal eyes in 18 male monkeys. Mean (SD) and interocular differences were obtained for each parameter from three independent measurements made during a 1 week period. Correlations among the topographic parameter...
متن کاملVariations of the Normal Human Limbal Stem Cells Detected by In Vivo Confocal Microscopy
Background To report normal variations of the limbal structures using in vivo laser scanning confocal microscopy. Methods: This was a retrospective study of fourteen eyes from 11 healthy individuals. Confocal imaging of cornea and limbus was performed using Heidelberg Retina Tomograph III Rostock Corneal Module. Results: The typical structure of the palisades of Vogt (POV) was detected ...
متن کاملReproducibility of the measurements of the optic nerve head topographic variables with a confocal scanning laser ophthalmoscope.
PURPOSE To determine the optic nerve head topographic parameters with the least variability in repeat measurements. METHODS We randomly selected and evaluated 1 eye each of 20 healthy subjects, a total of 20 eyes. We used the confocal scanning laser ophthalmoscope (CSLO) for optic nerve head analysis. The disc area and a total of 13 parameters were determined by Top SS. Each subject was exami...
متن کاملRelation of optic disc topography and age to thickness of retinal nerve fibre layer as measured using scanning laser polarimetry, in normal subjects.
AIMS To evaluate the relation of the optic nerve head topographic measurements and age with the thickness of the retinal nerve fibre layer (RNFL) in normal Caucasoid subjects by means of scanning laser polarimetry and tomography. METHODS Topographic optic disc measurements and RNFL thickness values of 38 normal Caucasoid subjects of both sexes aged 20 to 78 were measured using a confocal scan...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 47 10 شماره
صفحات -
تاریخ انتشار 2006