Serum protein electrophoresis and immunofixation by a semiautomated electrophoresis system.

نویسندگان

  • X Bossuyt
  • A Bogaerts
  • G Schiettekatte
  • N Blanckaert
چکیده

Semiautomated agarose electrophoresis and immunofixation performed with Hydrasys-Hyrys (Sebia) were compared with conventional, manually performed methods, including cellulose acetate electrophoresis, immunoelectrophoresis, and immunofixation. Reference intervals for agarose electrophoresis with Hydrasys-Hyrys were determined. Within-run imprecision (CV) for fraction quantitation with the semiautomated system was between 1% (albumin) and 4.5% (beta-globulin). Total imprecision (CV) was between 2.7% (albumin) and 7.3% (beta-globulin). Semiautomated agarose electrophoresis showed linear correlation with cellulose acetate electrophoresis. Thirty-four specimens with monoclonal components were analyzed by manual immunoelectrophoresis and immunofixation and by Hydrasys. In one case, a light-chain disease was missed with Hydrasys when the sample was diluted 1:3 (the routine dilution) but not when the sample was assayed undiluted. In another case, the Hydrasys system revealed a small IgGA monoclonal component in addition to the IgA monoclonal component detected by the manual methods. In the other cases, no differences between the manual methods and the semiautomated method were seen with respect to paraprotein identification.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

False-negative serum protein electrophoresis in a sample with an IgM monoclonal protein by semiautomated gel electrophoresis.

To the Editor: In a recent report, Keren et al. (1 ) described a case in which the Sebia semiautomated electrophoresis method failed to demonstrate proteinuria in a 50-fold concentrated urine sample despite the presence of 2 g/24 h total protein. The reason for this failure was attributed to the presence of debris associated with cellular elements that interfered with the wicking of the urine i...

متن کامل

Detection of oligoclonal immunoglobulins in cerebrospinal fluid by an immunofixation-peroxidase method.

BACKGROUND The detection of intrathecal synthesis of immunoglobulins is used in the diagnosis of multiple sclerosis (MS). We tested the semiautomated immunofixation-peroxidase (IFPOD) technique, which uses high-resolution agarose gel electrophoresis (HRAGE) directly followed by immunofixation with a peroxidase-labeled anti-IgG antiserum to detect oligoclonal immunoglobulins in cerebrospinal flu...

متن کامل

Automated serum protein electrophoresis by Capillarys.

Capillary zone electrophoresis (CZE) of serum proteins is increasingly gaining impact in clinical laboratories. In this report, we evaluate automated capillary zone electrophoresis by Capillarys (Sebia, France). Within-run and between-run imprecision for the five electrophoretic fractions was <2% and <6%, respectively. Data obtained with Capillarys correlated with results obtained with agarose ...

متن کامل

Is this pathological?

CASE DESCRIPTION A 74-year-old woman with toxic nodular goiter, diabetes mellitus, depression, gastroesophageal reflux disease, and hypercholesterolemia had routine serum protein electrophoresis done for the first time. Her medications included metformin, levothyroxine, sertraline, rosuvastatin, and rabeprazole. The patient’s renal function was normal. Serum protein electrophoresis was carried ...

متن کامل

Alpha, beta, gamma of serum proteins: a long history of successfully resolved problems

Characterization of blood proteins for clinical purposes was initiated in the middle of the nineteenth century and serum protein electrophoresis was first developed in the 1930s by a Swedish biochemist Arne Tiselius. Today, clinical analysis of human serum proteins by the electrophoretic method that evolved from the original fluid method of Tiselius, through paper electrophoresis, cellulose ace...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 44 5  شماره 

صفحات  -

تاریخ انتشار 1998