Prevalence and clinical impact of stent fractures after femoropopliteal stenting.
نویسندگان
چکیده
OBJECTIVES The aim of this study was to investigate the occurrence and the clinical impact of stent fractures after femoropopliteal stenting. BACKGROUND The development of femoral stent fractures has recently been described; however, there are no data about the frequency and the clinical relevance. METHODS A systematic X-ray screening for stent fractures was performed in 93 patients. In total, 121 legs treated by implantation of self-expanding nitinol stents were investigated after a mean follow-up time of 10.7 months. The mean length of the stented segment was 15.7 cm. RESULTS Overall, stent fractures were detected in 45 of 121 treated legs (37.2%). In a stent-based analysis, 64 of 261 stents (24.5%) showed fractures, which were classified as minor (single strut fracture) in 31 cases (48.4%), moderate (fracture of >1 strut) in 17 cases (26.6%), and severe (complete separation of stent segments) in 16 cases (25.0%). Fracture rates were 13.2% for stented length < or =8 cm, 42.4% for stented length >8 to 16 cm, and 52.0% for stented length >16 cm. In 21 cases (32.8%) there was a restenosis of >50% diameter reduction at the site of stent fracture. In 22 cases (34.4%) with stent fracture there was a total stent reocclusion. According to Kaplan-Meier estimates, the primary patency rate at 12 months was significantly lower for patients with stent fractures (41.1% vs. 84.3%, p < 0.0001). CONCLUSIONS There is a considerable risk of stent fractures after long segment femoral artery stenting, which is associated with a higher in-stent restenosis and reocclusion rate.
منابع مشابه
Stent fractures after superficial femoral artery stenting
Stent fracture is one of the major factors compromising implanted stent patency due to its consequences including in-stent restenosis, thrombosis, perforation, and migration. Stent fracture can occur from stress (extrinsic or intrinsic) and biomechanical forces at different implantation sites. We report on 2 cases of stent fractures and pertinent literature. One patient, a 75-year-old male, pre...
متن کاملSafety, Efficacy and Clinical Outcome of Direct Stent Implantation
Conventional methods of stenting require predilatation, which potentially increase vessel wall injury and cost of the procedure. In this study, the safety and efficacy of direct AVE-S7 (Medtronic-USA) stent placement were evaluated in 100 patients. Quantitative coronary angiography was performed at the baseline and post-stent. Clinical follow-up was done up to 9 months. In 100 patients (76 male...
متن کاملTaking femoropopliteal excimer laser photoablation therapy to the next level: defining the role of the TURBO-Booster guiding catheter in the CELLO registry.
presented at the International Collegeof Angiology, 51st Annual World Congress;Beijing, China; October 25-28, 2009. 4. Laird J. RESILIENT trial. Available at: http://www.bardpv.com/_vascular/vas-prod-lifestent-resilient.php 5. Shammas NW, Coiner D, Shammas G, et al.Percutaneous lower extremity arterial interven-tions using balloon angioplasty versus SilverHawk atherectom...
متن کاملFemoropopliteal Artery Stent Fracture with Recurrent In-Stent Reocclusion and Aneurysm Formation: Successful Treatment with Self-Expandable Viabahn Endoprosthesis.
Primary stenting in femoropopliteal lesions of intermediate length has recently shown favorable outcomes. However, stent fractures are a concern after bare metal stent implantation. The incidence of stent fracture varies widely (ranging from 2% to 65%) depending on factors such as the treated lesions or stent type and may potentially lead to various complications. We reported a case of stent fr...
متن کاملClinical impact and risk stratification of balloon angioplasty for femoropopliteal disease in nitinol stenting era: Retrospective multicenter study using propensity score matching analysis
OBJECTIVE Nitinol stenting could bring the better outcome in endovascular therapy for femoropopliteal disease. However, it might be expected that recent marked advances in both device technology and operator technique had led to improved efficacy of balloon angioplasty even in this segment. The aims of this study were to evaluate the clinical impact of balloon angioplasty for femoropopliteal di...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 45 2 شماره
صفحات -
تاریخ انتشار 2005