BACKGROUND Data on the current situation of nuclear medicine practices in cardiology in Brazil are scarce. The International Atomic Energy Agency (IAEA) has recommended eight "good practices" to minimize patients' ionizing radiation exposure during myocardial perfusion scintigraphy (MPS). OBJECTIVES To assess the adoption of the eight good practices in MPS in Brazil. METHODS Cross-sectional study with data obtained by use of a questionnaire. All hypothesis tests performed considered a significance level of 5%. RESULTS We observed that 100% of the nuclear medicine services (NMS) assessed do not use thallium-201 as the preferred protocol. Regarding the use of technetium-99m, 57% of the NMS administer activities above the threshold recommended by the IAEA (36 mCi) or achieve an effective dose greater than 15 millisievert (mSv). The abbreviated stress-only myocardial perfusion imaging is not employed by 94% of the NMS; thus, only 19% count on strategies to reduce the radioactive doses. Approximately 52% of the NMS reported always performing dose adjustment for patient's weight, while 35% administer poorly calculated doses in the one-day protocol. CONCLUSION A considerable number of NMS in Brazil have not adopted at least six practices recommended by the IAEA. Despite the difficulties found in nuclear practice in some Brazilian regions, almost all obstacles observed can be overcome with no cost increase, emphasizing the importance of developing strategies for adopting "good practices" when performing MPS.
منابع مشابه
A study of demographic and clinical features of patients referred to the nuclear medicine department of a military hospital for myocardial perfusion scintigraphy
Introduction: It seems that demographic and clinical features of patients referred for myocardial perfusion scintigraphy (MPS) is different among populations and healthcare settings. The purpose of the current study is to evaluate the clinical features and risk factors of patients referred for myocardial perfusion scintigraphy to a military hospital. Methods: As a ...
متن کاملEffects of depression on myocardial perfusion scintigraphy [Persian]
Introduction: The relationship between depression and coronary artery disease is well established; however assessment of this relationship using functional and semi-quantitative imaging (myocardial perfusion scintigraphy) was lacking. The aim of this study was to assess the relationship between the severity of depression and the severity of myocardial perfusion abno...
متن کاملEvaluation of myocardial perfusion and function after kidney transplantation by Gated SPECT myocardial perfusion scintigraphy
Introduction: The aim of this study was to evaluate the effect of successful kidney transplantation (KT) on myocardial perfusion and left ventricular function by both qualitative (visual) interpretation and semiquantitative parameters, using myocardial perfusion scintigraphy with gated-single photon emission computed tomography (gated-SPECT) in patients suffering from end-stage renal disease. ...
متن کاملThe myocardial perfusion scintigraphy in asymptomatic diabetic patients
Introduction: Asymptomatic diabetic patients are at increased risk of cardiovascular complications. Myocardial perfusion scan may be effective in risk evaluation in this population. Methods: 106 asymptomatic diabetic patients (age: min: 37, max: 82, mean: 57.73±8.88), including 56 females (52.8%) and 50 males (47.2%) were enrolled in the study. Myocardial perfusion scintigraphy was performed b...
متن کاملThe first performance of myocardial perfusion scintigraphy, post intravenous Dipyridamole injection
SUMMARY Dipyridamolc-Thallium imaging is a relatively safe and accurate method to evaluate myocardial perfusion in patients who arc unable to exercise to a maximal exertion (5,6,8,9). A 51year-old woman was admitted to Taleghani hospital with clinical symptoms and signs of coronary artery disease. Intravenous dipyridamote-Thallium scan was performed in this case. In multiple views obtained f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 110 شماره
صفحات -