A study of Wideband MR imaging: SNR and CNR

نویسندگان

  • E. L. Wu
  • J-H. Chen
چکیده

Most of the MR image accelerating methods suffer from degradation of acquired images, which is often correlated with the degree of acceleration. However, Wideband MRI is a novel technique that transcends such flaws. In this study we demonstrate that Wideband MRI is capable of obtaining images with identical quality as conventional MR images in terms of SNR, CNR (contrast-to-noise ratio) and image sharpness, while using only half the total scan time (Wideband factor W=2) of normal MRI sequence. Introduction The concept of Wideband MRI is based on the multi-carrier modulation technique in wireless communications and it increases the bandwidth in MRI. Wideband MRI simultaneously excites and acquires multiple slices using signals with multiple frequencies. RF pulses in Wideband MRI contains several bands, we define the number of bands as “Wideband multi-slice/slab factor W”. It is the excitation/acquisition of this wideband signal that provides additional information necessary for acceleration. We have reported Wideband MRI acceleration technique and its potential previously [1]. Several promising applications can be realized with the help of this technique and we have demonstrated them successfully [2,3,4]. Nevertheless, image properties of the Wideband MRI technique have to be thoroughly examined in order to ensure its feasibility and validity. Materials and methods To compare the image quality with and without wideband MRI, two identical standard Bruker head phantoms were used. Each phantom has several structures for image quality analysis. There are 1.4mm and 1mm wide horizontal and vertical stripes specifically tailored for image resolution assessment while some cylindrical structures containing oil and porous materials can be used for contrast evaluation. All images were acquired on a 3T Bruker Biospec MR imaging system, with the use of 8826 head coil. The two phantoms were placed 14cm apart along the axial direction in the RF coil. Axial images of the two phantoms were first taken separately without using the Wideband MRI technique. Then a Wideband factor of W=2 was applied by a modified Sinc RF pulse to obtain simultaneously the images of both phantoms using half the total scan time. Imaging parameters are listed as below: FOV=19cmx19cm, total Matrix size=256x256, gradient echo sequence with TR/TE=30/6.3ms. To analyze the image, SNR signal was sampled from 9 uniform areas throughout the image and noise was calculated as the standard deviation at four corners of the image. Results As shown in the figures below, sets of images taken with and without the use of Wideband MRI were named as W1 and W2. Images of phantom A and B were labeled after the Wideband acceleration factor. In Fig.1, images were placed side by side to compare the details. There are no visible differences between images acquired by the conventional method (W1-A & W1-B) and W=2 wideband accelerated images (W2-A & W2-B). In the close-ups, both horizontal and vertical stripes of W1 and W2 look identical. Additionally, there are neither visible image distortions nor artifacts. The quantified SNR and contrast comparison can be found in Fig. 2. We can clearly see that W2-A has a 1.9% SNR drop while W2-B has a 4% gain. Contrast analysis also shows small difference where W2-A has 3.3% less CNR than W1-A, and W2-B has a 2% increase from W1-B. It seems that phantom A has losses in both SNR and contrast while phantom B shows the opposite. The trends in SNR and contrast of phantom A and B may be explained as the RF inhomogeneity at different locations. Nonetheless the differences can be viewed as statistical errors, indicating that Wideband accelerated images has the same image quality as normal MR images. Fig. 1 Comparison between image taken without Wideband acceleration Fig.2 SNR and contrast comparison chart. Both SNR and contrast of (W1-A & W1-B) with W=2 Wideband acceleration (W2-A&W2-B;) and W=2 accelerated images have negligible difference from W=1 images ConclusionThe results strongly substantiate our claim that Wideband accelerated MR images bear no loss in image quality. We also expect the same result in other MRIsequences using Wideband acceleration. We believe it is self-evident that Wideband MRI is a powerful MRI accelerating technique that can maintain the same imagequality of each accelerated image while other acceleration methods suffer from degradation such as SNR loss or artifacts. Since Wideband MRI accelerates by the increase in bandwidth instead of k-space or image space alteration, properties stated in this study can be further extended into higher Wideband accelerated images.References[1] Wideband MRI: A New Dimension of MR Image Acceleration, Edzer L. Wu et al. Proc. Intl. Soc. Mag. Reson. Med. 17 (2009) [2]3D Isotropic Brain Imaging Using Wideband MRI, Edzer L. Wu et al. Proc. Intl. Soc. Mag. Reson. Med. 17 (2009)[3] Reduction of Diffusion Tensor Imaging Acquisition Time with Wideband MR Imaging, Edzer L. Wu et al. Proc. ISMRM. 17 (2009) [4] Wideband Parallel Imaging, Fu-Hsing Wu et al. Proc. Intl. Soc. Mag. Reson. Med. 17 (2009) Proc. Intl. Soc. Mag. Reson. Med. 18 (2010)4957

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimizing the Imaging Protocol for Ex Vivo Coronary Artery Wall Using High-Resolution MRI: An Experimental Study on Porcine and Human

OBJECTIVE To optimize the MR imaging protocol for coronary arterial wall depiction in vitro and characterize the coronary atherosclerotic plaques. MATERIALS AND METHODS MRI examination was prospectively performed in ten porcine hearts in order to optimize the MR imaging protocol. Various surface coils were used for coronary arterial wall imaging with the same parameters. Then, the image param...

متن کامل

Non-rigid registration and KLT filter to improve SNR and CNR in GRE-EPI myocardial perfusion imaging.

The purpose of the study was to evaluate the effect of motion compensation by non-rigid registration combined with the Karhunen-Loeve Transform (KLT) filter on the signal to noise (SNR) and contrast-to-noise ratio (CNR) of hybrid gradient-echo echoplanar (GRE-EPI) first-pass myocardial perfusion imaging. Twenty one consecutive first-pass adenosine stress perfusion MR data sets interpreted posit...

متن کامل

High-Field Open versus Short-Bore Magnetic Resonance Imaging of the Spine: A Randomized Controlled Comparison of Image Quality

BACKGROUND The purpose of the present study was to compare the image quality of spinal magnetic resonance (MR) imaging performed on a high-field horizontal open versus a short-bore MR scanner in a randomized controlled study setup. METHODS Altogether, 93 (80% women, mean age 53) consecutive patients underwent spine imaging after random assignement to a 1-T horizontal open MR scanner with a ve...

متن کامل

Readout-Segmented Echo-Planar Imaging in Diffusion-Weighted MR Imaging in Breast Cancer: Comparison with Single-Shot Echo-Planar Imaging in Image Quality

OBJECTIVE The purpose of this study was to compare the image quality of standard single-shot echo-planar imaging (ss-EPI) and that of readout-segmented EPI (rs-EPI) in patients with breast cancer. MATERIALS AND METHODS Seventy-one patients with 74 breast cancers underwent both ss-EPI and rs-EPI. For qualitative comparison of image quality, three readers independently assessed the two sets of ...

متن کامل

Improvement of the SNR and resolution of susceptibility-weighted venography by model-based multi-echo denoising

The vein structures of the brain are important for understanding brain function and structure, especially when functional magnetic resonance imaging (fMRI) is utilized, as fMRI is based on changes in the blood-oxygen-level-dependent (BOLD) signal, which is directly related to veins. The aim of the present study was to develop an effective method to produce high signal-to-noise-ratio (SNR) and h...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009