A reagent strip for measuring the specific gravity of urine.
نویسندگان
چکیده
A solid-phase reagent for determination of urinary specific gravity (relative density) is described. This reagent strip, similar to others in the "N-Multistix" series (Ames), contains a polyacid whose acidity is sensitive to the ionic concentration in the urine in which it is immersed. As the acidity of the polyacid changes, pH changes are detected by a pH indicator within the reagent strip. In comparison studies, 84.4% of relative densities as measured with these reagent strips were within 0.005 of the corresponding results with a total-solids meter, and 89.9% were within 0.005 of the corresponding urinometer results. Adding a correction of +0.005 to the reagent-strip results for urines with high pH increased the percentage of results within 0.005 of the comparison method to 90.7% (TS meter) and 92.9% (urinometer). Lot-to-lot variability and reader-to-reader variability were both low. Reagent strip results are not affected by glucose, may be increased by albumin, and correlate with urea concentrations.
منابع مشابه
Comparison of 3 Methods to Assess Urine Specific Gravity in Collegiate Wrestlers.
OBJECTIVE: To investigate the reliability and validity of refractometry, hydrometry, and reagent strips in assessing urine specific gravity in collegiate wrestlers. DESIGN AND SETTING: We assessed the reliability of refractometry, hydrometry, and reagent strips between 2 trials and among 4 testers. The validity of hydrometry and reagent strips was assessed by comparison with refractometry, the ...
متن کاملURINE REAGENT STRIPS FOR URINALYSIS For the Semi-quantitative and qualitative detection of Glucose, Bilirubin, Ketone, Specific Gravity, Blood, pH, Protein, Urobilinogen, Nitrite, Leukocytes and Ascorbic Acid in Urine
1 TUP for Urinalysis are firm plastic strips to which several different reagent areas are affixed. Depending on the product being used, TUP provide tests for Glucose, Bilirubin, Ketone (Acetoacetic acid), Specific Gravity, Blood, pH, Protein, Urobilinogen, Nitrite, Leukocytes, and Ascorbic Acid in Urine. Test results may provide information regarding the status of carbohydrate 1,2 metabolism, k...
متن کاملDiagnostic Value of Measurement Specific Gravity by Refractometric and Dipstick Method in Differentiation between Transudate and Exudate in Pleural and Peritoneal Fluid
Background: Accumulation of pleural and peritoneal fluid is seen in some diseases. In order to diagnose the disease and start the treatment, one of the most important actions will be to differentiate between exudates and transudates. The objective of this study was to determine the diagnostic value of measuring the specific gravity of the fluid through...
متن کاملDevelopment of a Urine Strip Analyzer Using Artificial Neural Network Using an Android Phone
Point of Care Testing (POCT) improves clinical process outcome. It has the potential to reduce errors and the wastage of resources. There is a significant amount of information obtained through the examination of urine. The routine urinalysis consists of two major components: physiochemical determination and microscopic examination of urine sediment. The physiochemical determination includes th...
متن کاملUrine Reagent Strips for Urinalysis
This Package Insert to be used with the following products: • URS-1B • URS-1G • URS-1P • URS-1K • URS-2K • URS-2P •URS-2LP • URS-3 • URS-4B • URS-4S • URS-5K • URS-5U • URS-6 • URS-6L • URS-7 • URS-8 • URS-9 • URS-10 • URS-11 For the semi-quantitative and qualitative detection of Glucose, Bilirubin, Ketone, Specific Gravity, Blood, pH, Protein, Urobilinogen, Nitrite, Leukocytes and Ascorbic Aci...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 28 10 شماره
صفحات -
تاریخ انتشار 1982