Contrast-enhanced versus non-enhanced three-dimensional echocardiography of left ventricular volumes.

نویسندگان

  • J A van der Heide
  • H F J Mannaerts
  • L Yang
  • G T Sieswerda
  • C A Visser
  • O Kamp
چکیده

BACKGROUND In three-dimensional echocardiography (3DE), individual endocardial trabeculae are not clearly visible necessitating left ventricular (LV) volumes to be measured by tracing the innermost endocardial contour. Ultrasound contrast agents aim to improve endocardial definition, but may delineate the outermost endocardial contour by filling up intertrabecular space. Although measurement reproducibility may benefit, there may be a significant influence on absolute LV volume measurements. METHODS Twenty patients with a recent myocardial infarction and good ultrasound image quality underwent 3DE using the TomTec Freehand method before and during continuous intravenous contrast infusion. LV volumes were measured offline using TomTec Echo-Scan software. RESULTS The use of contrast enhancement increased end-diastolic (110+/-35 vs. 144+/-53 ml; p<0.01) and end-systolic volume measurements (68+/-31 vs. 87+/-45 ml; p<0.01) significantly compared with non-contrast; the ejection fraction remained unchanged (40+/-13 vs. 41+/-14%, p=NS). Measurement reproducibility did not improve significantly, however. CONCLUSION Volumes measured by 3DE are significantly larger when ultrasound contrast is used. Possibly, intertrabecular space comprises a substantial part of the LV cavity. In the presence of an adequate apical acoustic window, ultrasound contrast does not improve LV volume measurement reproducibility. (Neth Heart J 2008;16:47-52.).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contrast Enhanced Echocardiography for Detection of Intrapulmonary Shunts in Liver Transplant Candidates

Background: Intrapulmonary vascular abnormalities associated with liver cirrhosis may result in intrapulmonary right-to-left shunt and hypoxemia. The aim of this study was to use contrast enhanced echocardiography to detect intrapulmonary vascular abnormalities in patients with liver cirrhosis candidates for liver transplantation. Methods: One hundred and two adult patients underwent contrast e...

متن کامل

Analysis of left ventricular volumes and function: a multicenter comparison of cardiac magnetic resonance imaging, cine ventriculography, and unenhanced and contrast-enhanced two-dimensional and three-dimensional echocardiography.

BACKGROUND Contrast echocardiography improves accuracy and reduces interreader variability on left ventricular (LV) functional analyses in the setting of two-dimensional (2D) echocardiography. The need for contrast imaging using three-dimensional (3D) echocardiography is less defined. The aim of this multicenter study was to define the accuracy and interreader agreement of unenhanced and contra...

متن کامل

‘Honeycomb appearance’ on three-dimensional transthoracic echocardiography as the landmark of left ventricular non-compaction: two case reports

INTRODUCTION Left ventricular non-compaction is a rare congenital heart disease, and is most commonly diagnosed via two-dimensional echocardiography according to echocardiographic criteria. Recently, transthoracic three-dimensional echocardiography has become available in the clinical setting. CASE PRESENTATION We present two isolated cases of left ventricular non-compaction from Japan (in an...

متن کامل

Comparison of contrast enhanced three dimensional echocardiography with MIBI gated SPECT for the evaluation of left ventricular function

BACKGROUND In clinical practice and in clinical trials, echocardiography and scintigraphy are used the most for the evaluation of global left ejection fraction (LVEF) and left ventricular (LV) volumes. Actually, poor quality imaging and geometrical assumptions are the main limitations of LVEF measured by echocardiography. Contrast agents and 3D echocardiography are new methods that may alleviat...

متن کامل

Comparison of left ventricular ejection fraction values obtained using invasive contrast left ventriculography, two-dimensional echocardiography, and gated single-photon emission computed tomography

OBJECTIVES Left ventricular ejection fraction can be measured by a variety of invasive and non-invasive cardiac techniques. This study assesses the relation of three diagnostic modalities to each other in the measurement of left ventricular ejection fraction: invasive contrast left ventriculography, two-dimensional echocardiography, and quantitative gated single-photon emission computed tomogra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation

دوره 16 2  شماره 

صفحات  -

تاریخ انتشار 2008