Dosimetric evaluation of hybrid brass/stainless-steel apertures for proton therapy.
نویسندگان
چکیده
In passive scattering proton therapy, patient specific collimators (apertures) are used to laterally shape the proton beam, and compensators are employed to distally conform proton dose to the target. Brass is a commonly used material for apertures and recently a hybrid brass/stainless-steel (BR/SST) aperture design has been introduced to reduce treatment cost without clinical flow change. We measured stopping power and leakage dose for apertures made of stainless steel and brass in the Proton Therapy system. The linear stopping power ratios for stainless steel (type 304) and brass to water were calculated to be 5.46 and 5.51, respectively. Measured stopping power ratios of SST and BR were 5.51 ± 0.04 and 5.56 ± 0.08, respectively, which agrees with the calculated values within 1%. Leakage dose on the downstream surface of two slabs of Ø18 cm stainless steel apertures (total thickness of 6.5 cm) for the maximum available proton energy (235 MeV) was 1.283% ± 0.004% of the prescription dose, and was smaller compared to the 1.358% ± 0.005% leakage dose measured for existing brass apertures of identical physical dimensions. Therefore, the existing beam range limits for brass aperture slabs used at our institution with safety margin allowances for material composition and delivered beam range uncertainties can be safely applied for the new BR/SST aperture design. Potential range differences in the brass and stainless steel interface regions of the hybrid design were further investigated using EBT3 GafChromic film. Film dosimetry revealed no discernible range variations across the brass and stainless steel interface regions. Neutron dose to the patient from brass and stainless steel apertures was simulated using the Monte Carlo method. The results indicate that stainless steel produces similar patient neutron dose compared to brass. Material activation dose rates of stainless steel were measured over a period of 7 d after irradiation. The measurements showed that the proton induced SST activity is initially lower and also decays at a faster rate than that induced in brass, therefore requires no changes in radiation protection requirements on material disposals. The Monte Carlo simulation confirmed higher initial activity of brass than stainless steel shortly after irradiation. The hybrid BR/SST aperture design is suitable for clinical use to replace the current brass apertures for all clinically used proton ranges. The existing aperture disposal procedures also satisfy radiation protection requirements for the new hybrid type apertures.
منابع مشابه
Proton radiotherapy dose perturbations caused by esophageal stents of varying material composition are negligible in an experimental model
BACKGROUND Self-expanding metal and plastic esophageal stents (SEMS and SEPS, respectively) are used in conjunction with chemoradiation for palliation of malignant dysphagia. To date, the dosimetric effects of stents undergoing proton radiotherapy are not known. STUDY AIM To investigate the proton radiotherapy dose perturbations caused by esophageal stents of varying designs and materials und...
متن کاملGrowth of carbon nanostructures upon stainless steel and brass by thermal chemical vapor deposition method
The lack of complete understanding of the substrate effects on carbon nanotubes (CNTs) growth poses a lot oftechnical challenges. Here, we report the direct growth of nanostructures such as the CNTs on stainless steel 304and brass substrates using thermal chemical vapor deposition (TCVD) process with C2H2 gas as carbon sourceand hydrogen as supporting gas mixed in Ar gas flow. We used an especi...
متن کاملSimultaneous hydroforming of bulge- and T-zone in 304 stainless steel and 70/30 brass tubes
Hydroforming process is largely used for the production of tubular parts in various industries, and has advantages such as less weight, higher quality, more strength and fewer production cost compared to the conventional methods of production. The aim of this study is forming a tube-shaped part with a special geometry that has both bulge- and T-zones with tube hydroforming process. The forming ...
متن کاملA Modified Hybrid MoM-Modal Method for Shielding Effectiveness Evaluation of Rectangular Enclosures with Multiple Apertures
A new hybrid modal-moment method is proposed to calculate fields penetrated through small apertures on rectangular metallic enclosures. First, the method of moments is used to numerically solve the governing electric field integral equation for the equivalent two-dimensional surface-current distributions on the surface of metallic enclosure including any number of rectangular apertures of arbit...
متن کاملTowards sustainable machining of 17-4 PH stainless steel using hybrid MQL-hot turning process
The use of a minimum quantity of lubrication (MQL) with extremely low consumption of lubricant in machining processes has been reported as a technologically and environmentally feasible alternative to conventional flood cooling. In hot machining, the external heat source is applied during machining that will assist to increase machining performance. Many external heating techniques are availabl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 59 17 شماره
صفحات -
تاریخ انتشار 2014