Wideband MRI: A New Dimension of MR Image Acceleration

نویسندگان

  • E. L. Wu
  • J-H. Chen
چکیده

We propose a new paradigm of MRI acceleration using the frequency multiplexing technique in modern communication technology; we name it “Wideband MRI”. A major component of wideband MRI is frequency multiplexing of MR signals. Using simultaneous multi-slice RF excitation pulses centered at different frequencies followed by simultaneous multi-slice acquisition during readout, the total scan time of a subject can be significantly reduced using existing hardware. Mathematical model and experimental results explain Wideband MRI image quality and serves as a criterion to evaluate the tradeoff between imaging speed and image quality in future applications. Introduction Faster MRI acquisition has always been an unceasing pursuit of all MRI practitioners. From Multi-Slice Multi-Echo to parallel imaging, acceleration methods of MRI have exploited in both temporal and spatial domains. However, the usage of signal bandwidth in MRI equipments remains to be highly inefficient compared to its radio-frequency sibling in communication, which has a speed improvement of 1000 folds within the last few decades. Previous attempts using multiple bandwidths such as simultaneous multi-slice acquisition [1,2,3] have failed. Not only do they leave the image quality an unsolved issue, but more importantly lack the comprehension of acceleration in the frequency domain. Possessing the knowledge of modern digital communication, we summarize the whole topic from a more generic perspective the concept of wideband multiple-input multiple-output (MIMO). Another mission is to reason the image quality scientifically with the equation and experiments we have derived. Material and method RF pulses in Wideband MRI contains several bands, we define the number of bands as “Wideband multi-slice/slab factor W”. It is the excitation/acquisition of this wideband signal that provides additional information that makes acceleration possible. Also with the additional separation gradient, voxels experience a shear along the direction of spatial encoding where separation gradient is added. By identifying the true mechanism of this effect, the relation between blurred pixels and separation gradient strength is established. It is an explicit statement that, for fixed in-plane resolution and readout gradient strength, the number of blurred pixel is proportional to the product of slice thickness and separation gradient strength. Two sets of experiments were designed to prove that image thickness and separation gradient strength is the two factors that determine image quality of Wideband MRI. The first set of experiment observes the equation by adjusting slice thickness and separation gradient strength with a phantom. After the equation is observed, we apply this imaging criterion on applications such as phantom, human knee and brain. Results Sets of 2D Wideband MRI are taken, The phantom images shows linearity between blurred pixels slice thickness or separation gradient strength, proving our theory and calculations to be correct. Several fine 2D in vivo images were taken with W greater or equal to 2 with fine image quality. These images are shown in Fig. 2&3. Scan time for each setting is reduced more than 50% compared to conventional sequences with the use of wideband MRI. The same wideband acceleration concept is also implemented on 3D MR imaging, exciting/acquiring multiple slab simultaneously. Shown in Fig. 4, excellent image quality of whole brain with fine contrast and details is acquired in only 1/4 the original acquisition time. Fig. 1 linearity of slice thickness Fig.2 W=3 2D192x192x192 knee image, Fig.3 W=2 2D192x192x128 whole brain Fig.4 W=4 3D 256x256x256 brain image v.s. blur. 6,3,2,1 pixel blurs from scan time=6 min8sec, 3X reduction from anatomy image, scan time=6min8sec, scan time=8min11sec, a 4X reduction from top to bottom.18min.2X reduction from 13min32min45sec.Discussion & ConclusionWe have shown that imaging time is directly divided by Wideband multi-slice/slab factor (W), because more information is captured with the increase of signal bandwidth. Also by proving equation 1., the tradeoff between number of blurred pixels and acquisition settings is lucid. This equation serves as a guideline for futureattempts to use Wideband MRI acceleration. MR practitioners are able to determine the optimal combination of acceleration and image quality according to this rule.The optimal 2D Wideband multi-slice factor (W) is 3 on our current MR system for subject the size of human head, it may be higher for machines with strongergradients (wider bandwidth) and able to excite thinner slices accurately. Wideband 3D imaging sequence is a highly efficient method to reduce slice thickness by simplyadding more steps of encoding along slice direction. From our results at least 4 times acceleration can be achieved on our human system with Wideband 3D MRI, even8~10 times can be obtained depending on the subject’s geometry. According to its characteristics, wideband MRI is most ideal for applications obtaining large coveragesuch as whole human body screening. Finally, what makes Wideband MRI so exciting is that it is accelerated on a dimension orthogonal to MSME and parallel imaging,meaning that one can gain unthinkable speed with the combination of these methods altogether. Moreover, Wideband MRI is compatible to almost every existing MRsequence. It allows a direct speedup to these sequences, and the world of MRI as well.References[1]Weaver JB. Simultaneous multislice acquisition of MR images. Magn Reson Med 1988;8:275 – 84. [2]Simultaneous parallel inclined readout image technique, Martyn N.J.et. al., Magnetic Resonance Imaging 24 (2006) 557–562[3] Ultra-fast Brain MR Imaging Using Simultaneous Multi-slice Acquisition Technique, Edzer L.Wu et. al.,Conf Proc IEEE Eng Med Biol Soc. 2007 Proc. Intl. Soc. Mag. Reson. Med. 17 (2009)2678

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A study of Wideband MR imaging: SNR and CNR

Most of the MR image accelerating methods suffer from degradation of acquired images, which is often correlated with the degree of acceleration. However, Wideband MRI is a novel technique that transcends such flaws. In this study we demonstrate that Wideband MRI is capable of obtaining images with identical quality as conventional MR images in terms of SNR, CNR (contrast-to-noise ratio) and ima...

متن کامل

Method for reducing of noise by improving signal-to-noise-ratio in wireless LAN

The signal to noise ratio (SNR) is one of the important measures for reducing the noise.A technique that uses a linear prediction error filter (LPEF) and an adaptive digital filter (ADF) to achieve noise reduction in a speech and image degraded by additive background noise is proposed. Since a speech signal can be represented as the stationary signal over a short interval of time, most of speec...

متن کامل

New Pseudo-CT Generation Approach from Magnetic Resonance Imaging using a Local Texture Descriptor

Background: One of the challenges of PET/MRI combined systems is to derive an attenuation map to correct the PET image. For that, the pseudo-CT image could be used to correct the attenuation. Until now, most existing scientific researches construct this pseudo-CT image using the registration techniques. However, these techniques suffer from the local minima of the non-rigid deformation energy f...

متن کامل

Quantitative Comparison of SPM, FSL, and Brainsuite for Brain MR Image Segmentation

Background: Accurate brain tissue segmentation from magnetic resonance (MR) images is an important step in analysis of cerebral images. There are software packages which are used for brain segmentation. These packages usually contain a set of skull stripping, intensity non-uniformity (bias) correction and segmentation routines. Thus, assessment of the quality of the segmented gray matter (GM), ...

متن کامل

Measurement of the correlation coefficients between extracted features from CT and MR images

Introduction: Nowadays applying computer in image processing is being improved revolutionary for solving medical images deficiencies. Image features that are analysis in image processing show image information. The aim of the present study was to find correlation between CT- scan and MRI images' features. Materials and Methods: After data acquisition, applying...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008