3D pulmonary perfusion MRI with radial ultra-short echo time and spatial-temporal constrained reconstruction
نویسندگان
چکیده
Figure 4. Quantitative evaluation of PBF (ml blood/100ml lung/min), PBV (ml blood/100ml lung) and MTT s in a 23 years old female patient with Factor V Leiden using PCB+ST reconstruction. 3D pulmonary perfusion MRI with radial ultra-short echo time and spatial-temporal constrained reconstruction Grzegorz Bauman, Kevin M Johnson, Laura C Bell, Julia V Velikina, Alexey A Samsonov, Scott K Nagle, and Sean B Fain Department of Medical Physics, University of Wisconsin-Madison, Madison, WI, United States, Department of Radiology, University of Wisconsin-Madison, Madison, WI, United States
منابع مشابه
Ultra-Fast Image Reconstruction of Tomosynthesis Mammography Using GPU
Digital Breast Tomosynthesis (DBT) is a technology that creates three dimensional (3D) images of breast tissue. Tomosynthesis mammography detects lesions that are not detectable with other imaging systems. If image reconstruction time is in the order of seconds, we can use Tomosynthesis systems to perform Tomosynthesis-guided Interventional procedures. This research has been designed to study u...
متن کاملA modified EPI sequence for high-resolution imaging at ultra-short echo time.
A robust modification of echo-planar imaging dubbed double-shot echo-planar imaging with center-out trajectories and intrinsic navigation (DEPICTING) is proposed, which permits imaging at ultra-short echo time. The k-space data is sampled by two center-out trajectories with a minimal delay achieving a temporal efficiency similar to conventional single-shot echo-planar imaging. Intersegment phas...
متن کاملRapid 3D-Sodium MRI of Knee Joint In-vivo at 7T
Introduction Loss of glycosaminoglycans (GAG) is a signature of early osteoarthritis (OA). Although sodium MRI has been shown to correlate linearly with GAG concentration (1, 2), it poses major challenges at clinical magnetic field strengths (1.5T/3.0T) in terms of low signal-to-noise (SNR), poor spatial resolution and long acquisition times due to low natural abundance, low sodium concentratio...
متن کاملAccelerated myocardial perfusion MRI using motion compensated compressed sensing (MC-CS)
single coil from a stress perfusion exam is considered. Few spatial frames and the image time profile are shown for the temporal TV constrained reconstruction (first row), and the proposed method (second row). The TV reconstruction had temporal blurring especially evident in frames with high motion (see arrows in top row). In contrast, the proposed scheme had crisper images with better temporal...
متن کاملUltra high spatio-temporal resolution hepatic MRI using a novel 2-point Dixon time resolved 3D SPGR sequence at 3T
Introduction: Dynamic contrast enhanced MRI (DCEMRI) is commonly used in abdominal-pelvic imaging for detection and characterization of primary and metastatic lesions. Current methods have adequate spatial resolution but the temporal resolution is often insufficient for visualization of hypervascular tumors. Optimal timing of the contrast arrival and robust fat suppression are the two critical ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2013