Automatic measurement of surface tension from noisy images using a component labeling method

نویسنده

  • Yi Y. Zuo
چکیده

Automatic surface tension measurement of turbid liquids using a bubble method (e.g., pendant/captive bubble) or interfacial tension measurement f some liquid–liquid systems necessitates an image analysis scheme robust against noise. Measuring the surface tension of lung surfactant–polymer ystems using the combination of axisymmetric drop shape analysis (ADSA) and a captive bubble is such an example. We have recently developed sophisticated image analysis scheme featuring the combination of the Canny edge detector and a novel edge smoothing technique called xisymmetric liquid fluid interfaces-smoothing (ALFI-S). The Canny edge detector is highly noise-resistant and ALFI-S is efficient in further emoving noise close to the bubble profile (i.e., adhering noise). However, the procedure of eliminating noise far away from the bubble profile (i.e., solated noise) is still not satisfactory in the previous scheme. Here a component labeling method is developed to automatically remove isolated oise. Component labeling refers to the process of detecting connected objects in a digital image. Once labeling is completed, information, such as rea, location and pixel intensity, of these separate objects can be obtained. Hence, component labeling can be used as a region-based segmentation echnique that is capable of differentiating the bubble and the isolated noise. The new component labeling-based noise reduction method is used o analyze captive bubble images with different amounts of noise. It is found that with the help of the labeling procedure smooth edges can be etected with a simple set of user-specified parameters even from images with extensive noise. Combined with the previous image analysis scheme, he component labeling method significantly improves the effectiveness and reliability of ADSA in automatically measuring surface tension from oisy images. 2006 Elsevier B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automatic liver segmentation for volume measurement in CT Images

Computed tomography (CT) images have been widely used for diagnosis of liver disease and volume measurement for liver surgery or transplantation. Automatic liver segmentation and volume measurement based on the segmentation are the most essential parts in computer-aided diagnosis for liver CT as well as computer-aided surgery. However, liver segmentation, in general, has been performed by outli...

متن کامل

Automatic measurement of instantaneous changes in the walls of carotid artery with sequential ultrasound images

Introduction: This study presents a computerized analyzing method for detection of instantaneous changes of far and near walls of the common carotid artery in sequential ultrasound images by applying the maximum gradient algorithm. Maximum gradient was modified and some characteristics were added from the dynamic programming algorithm for our applications. Methods: The algorithm was evaluat...

متن کامل

Automatic detection of liver tumor motion by fluoroscopy images

Background: A method to track liver tumor motion signals from fluoroscopic images without any implanted gold fiducial markers was proposed in this study to overcome the adverse effects on precise tumor irradiation caused by respiratory movement. Materials and Methods: The method was based on the following idea: (i) Before treatment, a series of fluoroscopic images corresponding to different bre...

متن کامل

Image Stitching of the Computed Radiology images Using a Pixel-Based Approach

In this paper, a method for automatic stitching of radiology images based on pixel features has been presented. In this method, according to the smooth texture of radiological images and in order to increase the number of the extracted features after quality enhancement of initial radiology images, 45 degree isotropic mask is applied to each radiology image to observe the image details. After t...

متن کامل

Automatic classification of Non-alcoholic fatty liver using texture features from ultrasound images

Background: Accurate and early detection of non-alcoholic fatty liver, which is a major cause of chronic diseases is very important and is vital to prevent the complications associated with this disease. Ultrasound of the liver is the most common and widely performed method of diagnosing fatty liver. However, due to the low quality of ultrasound images, the need for an automatic and intelligent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007