Frequency Comparison of I -Stabilized Nd : YAG Lasers

نویسندگان

  • Feng-Lei Hong
  • Jun Ishikawa
  • Jun Yoda
  • Jun Ye
  • Long-Sheng Ma
  • John L. Hall
چکیده

A first international comparison of I2-stabilized Nd : YAG lasers has been made between the National Research Laboratory of Metrology (NRLM), Tsukuba, Japan, the Joint Institute for Laboratory Astrophysics JILA (formerly the Joint Institute for Laboratory Astrophysics), Boulder, CO, the National Institute of Standards and Technology (NIST), Boulder, and the University of Colorado, Boulder. The results of the comparison show that the square root Allan variance of the portable NRLM laser has reached 2 10 14 when the integration time is larger than 300 s. Matrix measurements were made for five hyperfine components from a6 to a10 of the R(56)32-0 line. The averaged frequency difference between the NRLM and JILA lasers for four measurements made on three separate days was 4996 Hz (NRLM-JILA, at 532 nm) with a standard deviation of 88 Hz.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sub-Hertz Relative F requency Stabilization of Two-Diode Laser-Pumped Nd : YAG Lasers Locked to a Fabry-Perot Interferometer

Abstrucr-Two-diode laser-pumped Nd : YAG lasers have been frequency stabilized to a commercial 6.327 GHz free spectral range Fabry-Perot interferometer yielding a best-case beatnote linewidth of 330 mHz. In addition, a Fabry-Perot interferometer with a free spectral range of 680 MHz, a linewidth of 25 kHz, and a finesse of 27 500 has been built and when it was substituted in place of the commer...

متن کامل

Portable I2-stabilized Nd: YAG laser for international comparisons

We have established a compact and transportable I2-stabilized Nd:YAG laser for international comparisons of laser frequency. The root Allan variance of the portable laser has reached 3 9 10 14 when the integration time is longer than 200 s. The results of an international comparison between the National Research Laboratory of Metrology (NRLM), Tsukuba, Japan and the JILA (formerly the Joint Ins...

متن کامل

Stabilization and frequency measurement of the I2-stabilized Nd: YAG laser

We report improved stabilization results for and progress toward a more accurate frequency measurement of the 532 nm iodine-stabilized system based on a frequency-doubled Nd : YAG ring laser. We confirm the CCL-adopted frequency well within its stated uncertainty ( 40 kHz).

متن کامل

Laser-assisted hair removal: comparison of long-pulsed alexandrite and long-pulsed Nd:YAG lasers, individually and in combination

Background and aim: Laser is one of the most recent techniques which has widespread use in the treatment of many skin diseases. This technique has been successfully used to remove unwanted hairs in hirsutism. The aim of this study was to evaluate and compare the efficacy and safety of long-pulsed 755 nm alexandrite and long-pulsed 1064 nm Nd: YAG lasers individually and in combination for perma...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999