Intracardiac recording by catheter electrode of accessory pathway depolarization.
نویسندگان
چکیده
At electrophysiologic study in a patient with the Wolff-Parkinson-White syndrome, intracardiac catheter recordings demonstrated a deflection that occurred 30 ms before ventricular activation. The rapid deflection was present during ventricular preexcitation but not during normal atrioventricular conduction. All QRS complexes were preexcited to varying degrees during atrial fibrillation, yet the deflection consistently preceded ventricular activation by 30 ms. This deflection most likely represents the rare recording of a Kent bundle depolarization with an intracardiac electrode catheter.
منابع مشابه
Identification of Pathway Fiber Orientation
The ability to record accessory atrioventricular (AV) pathway activation consistently may be uniquely beneficial in improving pathway localization, identifying anatomic relations, and providing insight into unusual conduction properties. For the purpose of recording left AV accessory pathway activation, an electrode catheter was specially designed for use in the coronary sinus. The orthogonal c...
متن کاملConduction During Radiofrequency Current Catheter Ablation of Midseptal Accessory Pathways
Background. Septal accessory atrioventricular (AV) pathways may be located in close vicinity of the His bundle-AV nodal conduction system. Attempts at surgical or electrical interruption of these pathways may therefore result in impairment of normal AV conduction. This study focuses on a subset of septal pathways with an atrial insertion located inside the triangle of Koch. In this study, they ...
متن کاملRadiofrequency catheter ablation in the treatment of Wolff-Parkinson-White syndrome
Introduction: Tachyarrhythmias in Wolf Parkinson White (WPW) syndrome, can be a life threatening factor. Antiarrhythmic drug therapy in this syndrome, has not been completely acceptable. Efficacy, safety and economy of Radio Frequency Catheter Ablation (RFCA) in western studies, has made it as the treatment of choice. In the present study, efficacy of RFCA in the ablation of accessory pathway...
متن کاملPreservation of atrioventricular nodal conduction during radiofrequency current catheter ablation of midseptal accessory pathways.
BACKGROUND Septal accessory atrioventricular (AV) pathways may be located in close vicinity of the His bundle-AV nodal conduction system. Attempts at surgical or electrical interruption of these pathways may therefore result in impairment of normal AV conduction. This study focuses on a subset of septal pathways with an atrial insertion located inside the triangle of Koch. In this study, they w...
متن کاملDirect endocardial recording from an accessory atrioventricular pathway: localization of the site of block, effect of antiarrhythmic drugs, and attempt at nonsurgical ablation.
We recorded a discrete 0.95 mV potential consistent with accessory atrioventricular pathway (AP) activation during serial electrophysiologic studies in a patient with Ebstein's anomaly and Wolff-Parkinson-White syndrome. Bipolar pacing from the catheter electrode in which the AP potential was recorded resulted in a stimulus-ventricle interval identical to the AP-ventricle interval during antegr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 1 2 Pt 1 شماره
صفحات -
تاریخ انتشار 1983