Elimination of matrix effect and simultaneous determination of multi-components in complex systems by matrix coefficient non-linearity multivariate calibration based on single point response signals.

نویسندگان

  • Tai-Ming Zhang
  • Bin Yuan
  • Yi-Zeng Liang
  • Juan Cao
  • Chun-Xiao Pan
  • Bin Ying
  • Di-Yi Lu
چکیده

In order to deal with the matrix effect in the simultaneous determination of multi-components in a complex system, we have developed a novel method named matrix coefficient multivariate calibration method (MCMCM) for simultaneously determining n analytes in complex systems. The calibration models of n analytes, which are based on the experimental data of known samples, are first transformed into n linear equations, and then the equations are solved to obtain matrix calibration coefficients of the analytes in congeneric samples. In this way, the concentrations of n analytes in the unknown sample could be obtained easily and simultaneously by solving another n-variate linear equations with the help of the matrix calibration coefficients obtained-above. The method proposed in this work has been tested by voltammetry and atomic absorption spectrometry (AAS) with satisfactory results. On determining the elements such as Cu, Pb, Cd, Ni, Zn, Fe, Mn, Co, Ca, Mg, etc. in synthetic samples, the relative standard deviations (RSDs) of the results were 0.91 - 4.5%, and the recoveries were 95.8 - 105%. For actual samples, the RSDs and the recoveries were 1.5 - 6.9 and 92.0 - 110%, respectively.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous spectrophotometric determination of ampicillin and penicillin in human plasma using multivariate calibration

An analytical methodology based on spectrophotometric and partial least squares (PLS) algorithm for thesimultaneous determination of ampicillin and penicillin in human plasma was developed and validated. Themultivariate model was developed as a binary calibration model and it was built and validated with anindependent set of synthesis and real samples in presence of matrix. It is shown how a de...

متن کامل

Spectrophotometric Simultaneous Kinetic Determination of Iodide and Iodate Using Partial Least-Squares Calibration Method in a Single Kinetic Run

A rapid, sensitive and versatile kinetic method is presented for the simultaneous spectrophotometric determination of iodide and iodate by partial least-squares regression (PLS) using original and derivate data named as absorbance and rate data. The method is based on the catalytic effect of the cited anions on the reaction rate between Ce(IV) and As(III) in 2 mol l?1 sulfuric acid medium. The ...

متن کامل

Simultaneous Monitoring of Multivariate-Attribute Process Mean and Variability Using Artificial Neural Networks

In some statistical process control applications, the quality of the product is characterized by thecombination of both correlated variable and attributes quality characteristics. In this paper, we propose anovel control scheme based on the combination of two multi-layer perceptron neural networks forsimultaneous monitoring of mean vector as well as the covariance matrix in multivariate-attribu...

متن کامل

Simultaneous Determination of Ibuprofen and Caffeine in Urine Samples by Combining MCR-ALS and Excitation-emission Data

Second order advantage of excitation-emission fluorescence matrix was applied for the simultaneous determination of ibuprofen and caffeine. The proposed method is based on the measurement of the native fluorescence and recording emission spectra of ibuprofen and caffeine in different excitation wavelengths. The mixture of these compounds was resolved by multivariate curve resolution coupled wit...

متن کامل

Elimination of Chemical and Spectral Interferences in Measurement of Trace Elements in Urine and Blood by Combined Electrodeposition-Electrothermal Atomic Absorption Spectrometry

A combined electrodeposition-ETAAS technique has been applied to the analysis of Pb, Cd, Co, Ni, Cr and Mn in biological samples in order to overcome interferences and to minimize sample pretreatment. It requires minimal sample preparation with the electrolysis process aiding partial decomposition of the organic matrix, adequate for the release and deposition of trace elements. In an initia...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 23 5  شماره 

صفحات  -

تاریخ انتشار 2007