Protein folding mechanisms studied by time-resolved electrospray mass spectrometry.

نویسندگان

  • Lars Konermann
  • Jingxi Pan
  • Derek J Wilson
چکیده

Mass spectrometry (MS) owes its remarkable rise as a bioanalytical tool to the development of two “soft” ionization techniques: matrix-assisted laser desorption/ ionization (MALDI) (1,2) and electrospray ionization (ESI) (3). The salient feature of soft ionization is that a wide range of analytes, from small metabolites to very large biomolecular systems, can be transferred intact into the gas phase, thus making them amenable to mass spectrometric analysis. For MALDI-MS, the sample is embedded into a crystalline matrix prior to analysis. For ESI, in contrast, ionization is initiated directly from the liquid phase by spraying analyte solution from the tip of an electrically charged capillary. The small droplets formed by the ESI emitter undergo rapid evaporation and fi ssion, ultimately releasing the analyte as multiply protonated (or deprotonated) species (4).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing equilibrium and kinetic protein unfolding using time-resolved electrospray-coupled ion mobility mass spectrometry.

Protein unfolding intermediates are thought to play a critical role in conformational pathogenesis, acting as a 'gateway' to inactivation or pathogenic aggregation. Unfolding intermediates have long been studied either by populating partially-folded species at equilibrium using incresingly denaturing conditions, or by transiently populating 'kinetic' intermediates under fully denaturing conditi...

متن کامل

Pulsed hydrogen exchange and electrospray charge-state distribution as complementary probes of protein structure in kinetic experiments: implications for ubiquitin folding.

The possible involvement of "hidden" kinetic intermediates in the apparent two-state folding of some proteins is currently a matter of debate. This study uses time-resolved electrospray ionization (ESI) mass spectrometry with on-line pulsed hydrogen-deuterium exchange (HDX) for monitoring the refolding of acid/methanol-denatured ubiquitin. It is demonstrated that the ESI charge-state distributi...

متن کامل

Protein-ligand and protein-protein interactions studied by electrospray ionization and mass spectrometry.

Electrospray ionization has made possible the transference of non-covalently bound complexes from solution phase to high vacuum. In the process, a complex acquires a net charge and becomes amenable to measurement by MS. FTICR (Fourier-transform ion cyclotron resonance) MS allows these ions to be measured with sufficiently high resolution for the isotopomers of complexes of small proteins to be ...

متن کامل

Conformational and noncovalent complexation changes in proteins during electrospray ionization.

Electrospray ion sources efficiently produce gas-phase ions from proteins and their noncovalent complexes. Charge-state distributions of these ions are increasingly used to gauge their conformations in the solution phase. Here we investigate how this correlation is affected by the spraying conditions at the early stage of droplet generation, prior to the ionization process. We followed the fold...

متن کامل

FOR THE RECORD Protein folding coupled to DNA binding in the catalytic domain of bacteriophage integrase detected by mass spectrometry

Bacteriophage integrase ( -Int) is the prototypical member of a large family of enzymes that catalyze site-specific DNA recombination via single-strand cleavage and the formation of a Holliday junction intermediate. Crystallographic and biochemical evidence indicate that substantial conformational change (i.e., folding) in the catalytic domain of the protein is required for substrate recognitio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • BioTechniques

دوره 40 2  شماره 

صفحات  -

تاریخ انتشار 2006