Ideal Integrating Bolometer

نویسندگان

  • A. Kogut
  • M. DiPirro
  • S. H. Moseley
چکیده

A bolometer consists of a thermometer with heat capacity C mounted on an absorbing substrate, weakly coupled to a bath at temperature T0 via a thermal conductance G ( Figure 1 ). Resistive bolometers (including both composite and transition-edge bolometers) use the temperature dependence of a resistive element to measure the infrared signal incident on the absorber. In steady-state operation, the thermometer heats up until the dissipated power matches the power conducted through the thermal link to the bath,

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bolometer theory pdf

A bolometer thermometer with a thermal capacity C is coupled to a temperature T. 0 through a heat conductivity G and receives the power.Bolometers made with a square mesh structure can be assembled. Show a wide feature of noise not explained by the basic theory. A bolometer is a device for measuring the power of incident electromagnetic radiation via the heating of a material with a temperature...

متن کامل

Numerical optimization of integrating cavities for diffraction-limited millimeter-wave bolometer arrays.

Far-infrared to millimeter-wave bolometers designed to make astronomical observations are typically encased in integrating cavities at the termination of feedhorns or Winston cones. This photometer combination maximizes absorption of radiation, enables the absorber area to be minimized, and controls the directivity of absorption, thereby reducing susceptibility to stray light. In the next decad...

متن کامل

Microcalorimeter and bolometer model

The standard nonequilibrium theory of noise in ideal bolometers and microcalorimeters fails to predict the performance of real devices due to additional effects that become important at low temperature. In this paper we extend the theory to include the most important of these effects and find that the performance of microcalorimeters operating at 60 mK can be quantitatively predicted. We give a...

متن کامل

Highly sensitive hot electron bolometer based on disordered graphene

A bolometer is a device that makes an electrical resistive response to the electromagnetic radiation resulted from a raise of temperature due to heating. The combination of the extremely weak electron-phonon interactions along with its small electron heat capacity makes graphene an ideal material for applications in ultra-fast and sensitive hot electron bolometer. However, a major issue is that...

متن کامل

Critical Temperature Dependence of High Frequency Electron Dynamics in Superconducting Hot-Electron Bolometer Mixers

Critical Temperature Dependence of High Frequency Electron Dynamics in Superconducting Hot-Electron Bolometer Mixers Irfan Siddiqi May, 2002 Superconducting diffusion-cooled hot-electron bolometer (HEB) mixers are ideal candidates for use in terahertz heterodyne spectroscopy (THz). This thesis investigates mixer performance as a function of the superconducting transition temperature (Tc). In th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001