[Development and validation of the MNREAD reading acuity chart in Portuguese].

نویسندگان

  • Celina Tamaki Monteiro de Castro
  • Christopher Scott Kallie
  • Solange Rios Salomão
چکیده

PURPOSE To create and to validate a version of the Minnesota Low Vision Reading Test (MNREAD) acuity chart for the Portuguese language. METHODS The Minnesota Low Vision Reading Test acuity chart contain 19 sentences (logMAR 0.5 to 1.3) with 60 characters printed on three lines. All the sentences must have the same length with simple vocabulary. A total of 110 sentences were generated. The sentences were presented to 36 subjects (20 adults and 16 children) and mistakes and reading time were marked. 38 sentences were selected for a prototype (MNREAD-P). Sentences with extreme high and low mean reading time, large standard deviation, and with persistent mistakes by subjects were excluded. VALIDATION Twenty subjects with normal vision (logMAR 0 or 20/20 or better, with best refractive correction) were tested with the MNREAD-P and read a passage of text, representing normal, day-to-day reading. Reading speeds in words per minute were recorded for both the MNREAD and the text passage. RESULTS Sentences in the MNREAD Portuguese chart are sufficiently consistent to provide reliable measures of reading abilities. Reading speeds for the passage (logMar = 0.6) were 197.8 words/minute and the maximum reading speeds calculated by the MNREAD-P were 200.1 words/minute. The correlation between the two measures was r = 0.82. CONCLUSION The MNREAD-P was tested on normal vision subjects and the results were the same from the original Minnesota Low Vision Reading Test. The reading speed measured on the MNREAD-P was statistically equivalent to the reading speed of the passage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of reading speed with 3 different log-scaled reading charts.

BACKGROUND A reading chart that resembles real reading conditions is important to evaluate the quality of life in terms of reading performance. The purpose of this study was to compare the reading speed of UiTM Malay related words (UiTM-Mrw) reading chart with MNread Acuity Chart and Colenbrander Reading Chart. MATERIALS AND METHODS Fifty subjects with normal sight were randomly recruited thr...

متن کامل

Comparing performance on the MNREAD iPad application with the MNREAD acuity chart

Our purpose was to compare reading performance measured with the MNREAD Acuity Chart and an iPad application (app) version of the same test for both normally sighted and low-vision participants. Our methods included 165 participants with normal vision and 43 participants with low vision tested on the standard printed MNREAD and on the iPad app version of the test. Maximum Reading Speed, Critica...

متن کامل

Reading acuity in children: evaluation and reliability using MNREAD charts.

PURPOSE To study reading acuity in children and assess the reliability of its measurement using the Italian version of the MNREAD reading chart. METHODS One hundred sixteen children from grades 3 to 8 with normal near vision were tested at a pediatric eye care institution in northeastern Italy. Visual acuity was evaluated with Early Treatment Diabetic Retinopathy Study (ETDRS) charts and read...

متن کامل

Baseline MNREAD Measures for Normally Sighted Subjects From Childhood to Old Age

PURPOSE The continuous-text reading-acuity test MNREAD is designed to measure the reading performance of people with normal and low vision. This test is used to estimate maximum reading speed (MRS), critical print size (CPS), reading acuity (RA), and the reading accessibility index (ACC). Here we report the age dependence of these measures for normally sighted individuals, providing baseline da...

متن کامل

Reading ability and quality of life in Stargardt disease.

PURPOSE To study the reading performance of patients with Stargardt disease (STGD) and the relationship between clinical vision measurements and vision-related quality of life (VRQOL). METHODS We studied both eyes of 16 patients with STGD. Each patient was examined for best-corrected visual acuity (Early Treatment Diabetic Retinopathy Study [ETDRS]), reading ability (MNREAD and REX charts), c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arquivos brasileiros de oftalmologia

دوره 68 6  شماره 

صفحات  -

تاریخ انتشار 2005