ECG-Triggered Dynamic Time-Resolved Magnetic Resonance Angiography of the Thoracic Aorta
نویسندگان
چکیده
J. C. Carr, D. N. Sandman, K. O'Hara, C. Rocha, T. Cashen, O. Simonetti, R. Kroeker, T. J. Carroll Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, United States, Siemens Medical Solutions, Chicago, IL, United States Introduction: Time-resolved subsecond contrast-enhanced magnetic resonance angiography (SS-MRA), which utilizes acquisition times of 700-800 msec per 3D data set, has been shown to be particularly useful for assessing high-flow abnormalities in the thoracic aorta, such as shunts and dissections. Because of the close proximity to the heart, cardiac motion artifact can frequently obscure subtle findings in the ascending aorta. Acceleration techniques for contrast-enhanced MRA using TREAT (time-resolved, echo-sharing, angiographic technique) and iPAT (intelligent parallel acquisition technique) have recently been developed. When these are used in combination with conventional SS-MRA, it is possible to reduce the acquisition time to less than 300 msec. With frame durations this short, it is possible to use ECGtriggering to gate the acquisition period to diastole, thereby eliminating any cardiac motion artifact. The purpose of this study was to compare conventional SS-MRA to ECG-gated contrast-enhanced MRA using TREAT and iPAT, for the assessment of thoracic aortic disease. Methods: 58 patients with suspected disease of the thoracic aorta underwent time-resolved contrast-enhanced MRA on Siemens 1.5T Sonata and Avanto scanners. All patients had correlative imaging with echocardiography, CT or conventional axial MRI. 31 patients were imaged using a conventional subsecond 3D FLASH sequence (SS-MRA) with short TR (TR/TE: 1.6/0.7; flip angle 20; 256 readout; 6 partitions; 2.6x1.4x15mm voxels). 27 patients were imaged with a newer pulse sequence, which combines SS-MRA with TREAT and iPAT. The TREAT sequence, which is based on the original TRICKS (time-resolved imaging of contrast kinetics) concept, uses a novel k space echo-sharing approach with elliptical centric reordering (fig. 2). When combined with iPAT, the acquisition time was 300 msec per 3D set. ECG-triggering was used to gate the acquisition period to diastole. Scanning parameters were similar to the conventional SS-MRA technique. For both techniques, imaging was carried out in an oblique sagittal orientation and 6cc of Gadolinium were injected at 6cc/sec. A quantitative analysis of vessel sharpness was performed for both techniques in five different anatomic locations (aortic root, ascending aorta, aortic arch, upper thoracic aorta, lower thoracic aorta). Two different methods were used. The first method involved generating a point-spread function across the vessel wall and calculating the upslope of the resultant curve. The second measure involved calculating the profile and distribution of signal intensities across the vessel lumen. Statistical comparisons were performed using a Students t-test, with significance determined at the 5% level. A qualitative analysis was also performed by two independent observers. Image quality and sharpness were scored on a scale of 1-5. Image artifact was graded on a 3 point scale. The results were compared using a student’s t-test. The presence of pathology in the thoracic aorta was also noted for both techniques. Results: Quantitative measurements of image sharpness were higher for the ECG-gated technique compared to the conventional SS-MRA (table 1). This was statistically significant in the aortic root (p<0.05). Qualitative values of image sharpness and quality were higher for the ECG-gated technique (p<0.001). There were fewer artifacts visible on the ECG-gated technique (p<0.001) compared to the conventional SS-MRA. Both techniques were equally accurate at detecting aortic pathology (100% sensitivity)
منابع مشابه
Blood Flow Simulation in an Aorta with a mild coarctation Using Magnetic Resonance Angiography and Finite Volume Method
Coarctation of the aorta is one of the five main congenital cardiovascular failures, accounting for 6–8 percent of these failures. This research aimed to simulate the blood flow of a seventeen-year-old male teen with a mild coarctation at one-third of his aorta's descending branch. The simulation was performed by extracting the domain and the input pulsatile velocity signal as the boundary cond...
متن کاملNon-contrast enhanced, EKG-triggered, navigator MR angiography of the thoracic aorta and proximal pulmonary arteries: initial evaluation of using an abdominal compression band to reduce acquisition times
Background Non-contrast enhanced, EKG-triggered, navigator 3DSSFP magnetic resonance angiography (NCE-MRA) is a robust technique but suffers from long scan acquisition times. Depending on heart and respiratory rates, acquisition times can still be prohibitively long. We describe the use of an abdominal compression band to reduce respiratory motion and image acquisition time with no sacrifice of...
متن کاملA Comparison between Gadofosveset Trisodium and Gadobenate Dimeglumine for Steady State MRA of the Thoracic Vasculature
PURPOSE Retrospective comparison between gadofosveset trisodium and gadobenate dimeglumine steady state magnetic resonance angiography (SS-MRA) of the thoracic vasculature at 1.5T using signal-to-noise ratio (SNR) and vessel edge sharpness (ES) as markers of image quality. MATERIALS AND METHODS IRB approval was obtained. Twenty separate patients each underwent SS-MRA using high-resolution 3D ...
متن کاملMagnetic resonance imaging of the thoracic aorta.
Magnetic resonance imaging (MRI) is steadily becoming recognized as a premier imaging modality for evaluating the thoracic aorta. Its noninvasive, nonimaging approach and refined resolution capabilities effectively combine the advantages of echocardiography, angiography, and computed tomography (CT) under the auspices of a single imaging device. On static spin-echo MRI, blood flow appears dark,...
متن کاملEvaluation and comparison of ECG-gated techniques at 1.5 T for contrast enhanced MR angiography of the thoracic aorta
Background 3D T1-weighted contrast-enhanced MRA (CE-MRA) is routinely used for non-invasive evaluation of the thoracic aorta. However, competing demands of high spatial resolution and fast (breath-hold) acquisition often preclude ECG-gating, leading to motion artifact at the aortic root. Standard Cartesian-sampled ECG-gated CE-MRA acquires 1 partition per heartbeat resulting in long scan times,...
متن کامل