Partial Discharge Monitoring Of Dielectrics Using Machine Oriented Algorithmic Techniques

نویسندگان

  • N. B. Bish
  • P. A. Howson
  • R. J. Howlett
  • T. J. Fawcett
  • D. A. Hilder
چکیده

Partial Discharge monitoring provides a tool for the assessment of failure risk for high voltage plant and equipment. The measurement process is complicated by the presence of interference, transients and other sources of disturbance on the system. In practical monitoring systems these disturbances almost certainly fall outside the boundaries of any expert system for PD recognition. Because of the complexities of PD measurement, only a sub-set of the available parameters is considered. There is currently no universal system capable of assessing and analysing partial discharge activity in samples outside of laboratory conditions. This paper describes continuing work to develop machine oriented and self training neural network systems to identify partial discharge taking into account localised characteristics and changing dielectric trends

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High Field Electrical Conduction and Breakdown in Solid Dielectrics: A Signal Denoising Techniques by Wavelet Transform

One of the most important challenges of on-site partial discharge measurement is to capture the original signal in a noisy environment. The different sources of noise which includes thermal or resister noise added by the measuring circuit, signals due to electromagnetic interferences. Sophisticated and proper methods are required to detect and measured the partial discharge signals. Fortunately...

متن کامل

Evaluating the Improvement of Partial Discharge Localization Accuracy Using Frequency Response Assurance Criterion

Partial Discharge (PD) is the most important source of insulation degradation in power transformers. In order to prevent catastrophic failures in transformers, PDs need to be located as soon as possible so that maintenance measures can be taken in time. Due to the structural complexity of windings, locating the PD source inside a transformer winding is not a simple task. In this paper, the effi...

متن کامل

A Novel Partial Discharge Calibrator Design via Dual Microconroller and High Speed Dac

Insulation is a crucial phenomenon for high voltage apparatus. Partial discharge activity affects the service life of the dielectrics. Therefore partial discharge must be less than a specified value for high voltage equipment. An accurate partial discharge measurement strongly depends on scaling of the measurement systems. It is a general method to use a partial discharge calibrator to calibrat...

متن کامل

Preventing Key Performance Indicators Violations Based on Proactive Runtime Adaptation in Service Oriented Environment

Key Performance Indicator (KPI) is a type of performance measurement that evaluates the success of an organization or a partial activity in which it engages. If during the running process instance the monitoring results show that the KPIs do not reach their target values, then the influential factors should be identified, and the appropriate adaptation strategies should be performed to prevent ...

متن کامل

EFFECT OF ELECTRIC FIELD ON PD ACTIVITY AND DAMAGE INTO SOLID DIELECTRIC MATERIALS

Abstract – In this paper, the effect of applied electric field on the damage due to partial discharges activity into the surroundings dielectrics of a narrow channel encapsulated within the volume of a dielectric material is evaluated using a kinetic model based on Particle in Cell - Monte Carlo Collision (PIC-MCC) model. After application of an electric field across a dielectric material which...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003