Myocardial T1 mapping using SMART1Map: initial in vivo experience

نویسندگان

  • Jeff A Stainsby
  • Glenn S Slavin
چکیده

Background Recently a single-point, saturation-recovery myocardial T1 mapping sequence (SMART1Map = Saturation Method using Adaptive Recovery Times for cardiac T1 Mapping) was presented [1]. Compared to common methods like MOLLI, SMART1Map measures true T1 instead of apparent T1 relaxation, is more time efficient and can track exact TI times instead of estimated ones based on the heart rate during prescription. In this work we compare SMART1Map to MOLLI in an initial cohort of volunteers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accelerated myocardial T1 mapping using SMART1Map and compressed sensing with temporal PCA

Background Myocardial T1 mapping has been proposed for characterizing a wide range of diffuse and focal fibrotic pathologies. Due to the demands of requiring multiple sample points along the signal relaxation curve in a breath-held ECG-gated scan, current T1 mapping methods have focused on single-shot acquisitions. Collecting all data in a quiescent time window has limited T1 mapping to a reduc...

متن کامل

True T1 mapping with SMART1Map (saturation method using adaptive recovery times for cardiac T1 mapping): a comparison with MOLLI

Background SMART1Map is a new single-point technique for cardiac T1 mapping [1]. Unlike Look-Locker approaches, such as MOLLI, which yield an “apparent” T1 (T1*), SMART1Map directly measures true T1. Because T1* is a function of imaging parameters, it is always shorter than T1, and correction methods are required to obtain the true T1. This work compared the accuracy of SMART1Map with MOLLI in ...

متن کامل

Comparing the accuracy and precision of SMART1Map, SASHA and MOLLI

Background Currently, MOLLI [1] is the most common method for measuring myocardial T1. Because MOLLI uses an SSFP-based Look-Locker approach, only the apparent T1 (T1*) can be measured, and there are concerns about the accuracy of the T1* values due to the dependence on imaging parameters. Alternatives to LookLocker imaging are single-point methods such as SASHA[2] and SMART1Map[3]. Although si...

متن کامل

A long way from the heart.

the gadolinium-enhanced myocardium: adjustment for factors affecting interpatient comparison. Magn Reson Med 2011;65:1407–15. 21. Schneider CA,Rasband WS, Eliceiri KW. NIH Image to ImageJ: 25 yearsof image analysis. Nat Methods 2012;9:671–5. 22. Flett AS, Hayward MP, Ashworth MT, Hansen MS, Taylor AM, Elliott PM et al. Equilibrium contrast cardiovascular magnetic resonance for the measurement o...

متن کامل

Reproducibility of free-breathing multi-slice native myocardial T1 mapping using the slice-interleaved T1 (STONE) sequence

Background Quantitative myocardial T1 mapping is a promising technique for assessment of interstitial diffuse fibrosis. Recently, a novel T1 mapping sequence for free-breathing, multi-slice, myocardial T1 mapping using the sliceinterleaved T1 (STONE) has been developed [1], which was shown to provide superior accuracy compared to MOLLI [2]. However, in-vivo reproducibility and precision of this...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2013