Differences in Aortic Valve and Left Ventricular Parameters Related to the Severity of Myocardial Fibrosis in Patients with Severe Aortic Valve Stenosis

نویسندگان

  • Inyoung Song
  • Sung Min Ko
  • Jeong Geun Yi
  • Hyun Keun Chee
  • Jun Seok Kim
چکیده

OBJECTIVE This study investigated the morphological and functional characteristics of the aortic valve and the left ventricular (LV) systolic functional parameters and myocardial mass related to the severity of myocardial fibrosis (MF) in patients with severe aortic valve stenosis (AS). MATERIALS AND METHODS We retrospectively enrolled 81 patients (48 men; mean age: 59±12 years) with severe AS who underwent transthoracic echocardiography (TTE), cardiac computed tomography (CCT), and cardiovascular magnetic resonance (CMR) within 1 month and subsequent aortic valve surgery. Degree of MF was determined on delayed contrast-enhanced CMR with visual sub-segmental analysis-based quantification and was classified into three groups (no, mild, and severe) for identifying the differences in LV function and characteristics of the aortic valve. One-way ANOVA, Chi-square test or Fisher's exact test were used to compare variables of the three groups. Univariate multinomial logistic regression analysis was performed to determine the association between the severity of MF and variables on imaging modalities. RESULTS Of 81 patients, 34 (42%) had MF (mild, n = 18; severe, n = 16). Aortic valve calcium volume score on CCT, aortic valve area, LV mass index, LV end-diastolic volume index on CMR, presence of mild aortic regurgitation (AR), transaortic mean pressure gradient, and peak velocity on TTE were significantly different among the three groups and were associated with severity of MF on a univariate multinomial logistic regression analysis. Aortic valve calcium grade was different (p = 0.008) among the three groups but not associated with severity of MF (p = 0.375). CONCLUSIONS A multi-imaging approach shows that severe AS with MF is significantly associated with more severe calcific AS, higher LV end-diastolic volume, higher LV mass, and higher prevalence of mild AR.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Current management of calcific aortic stenosis.

Calcific aortic stenosis is a progressive disease with no effective medical therapy that ultimately requires aortic valve replacement (AVR) for severe valve obstruction. Echocardiography is the primary diagnostic approach to define valve anatomy, measure aortic stenosis severity, and evaluate the left ventricular response to chronic pressure overload. In asymptomatic patients, markers of diseas...

متن کامل

بررسی نتایج پیگیری یک ساله بالون والولوپلاستی تنگی مادرزادی دریچه آئورت در کودکان به مدت 10 سال در بیمارستان قلب شهید رجایی

Abstract Background: Balloon valvuloplasty uses for treatment of aortic stenosis from 20 years ago. Regarding loss of information about results of balloon valvuloplasty of hereditary aortic stenosis, this study was done to determine prognosis and complication of balloon valvuloplasty during last 10 years. Methods: This study was done on existing data of all children with hereditary aortic...

متن کامل

Echocardiographic assessment of left ventricular function in aortic valve disease.

Echocardiography was used to study left ventricular size and contraction in 128 patients with isolated aortic valve disease -45 patients with aortic stenosis, 25 with mixed aortic valve disease and 58 with aortic regurgitation. Left ventricular measurements included the end-diastolic internal dimension (LVIDd), mural thickness (PWTd), an index of circumferential myocardial contraction-fractiona...

متن کامل

Bicuspid Aortic Valve: An Unusual Cause of Aneurysm of Left Coronary Sinus of Valsalva

Bicuspid aortic valve is traditionally considered an innocuous congenital anomaly. Due to a better and widespread availability of non-invasive imaging techniques, it has come to the fore that 30% of these cases develop complications, viz., valve abnormality (aortic regurgitation and stenosis), and aneurysm of aortic root and ascending aorta. Sinus of Valsalva aneurysm is an uncommon complicatio...

متن کامل

عوامل خطر تنگی هموگرافت پولمونر پس ازعمل جراحی Ross

Background: The Ross procedure has been known as a good method for aortic valve replacement. Pulmonary allograft postoperative stenosis subsequent to the Ross procedure has been noted as an important disadvantage of this technique, although risk factors related to this complication are not clearly recognized. In this study we evaluate the risk factors of pulmonary allograft stenosis after Ross ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017