The qualitative criterion of transient angle stability
نویسندگان
چکیده
In almost all the literatures, the qualitative assessment of transient angle stability extracts the angle information of generators based on the swing curve. As the angle (or angle difference) of concern and the threshold value rely strongly on the engineering experience, the validity and robust of these criterions are weak. Based on the stability mechanism from the extended equal area criterion (EEAC) theory and combining with abundant simulations of real system, this paper analyzes the criterions in most literatures and finds that the results could be too conservative or too optimistic. It is concluded that misjudgment would be taken if an angle (or angle difference) of concern departing from the concept of the controlling mode or a constant threshold value is used in the criterion.
منابع مشابه
Selection of Resistive and Inductive Superconductor Fault Current Limiters Location Considering System Transient Stability
Superconductor fault current limiter (SFCL) is an effective device to suppress high fault currents. This paper presents a comparative study of resistive and inductive fault current limiters from transient stability point of view. Appropriate location and type of the limiters in a HV substation is selected by a qualitative approach based on the equal area criterion. Study system is simulated by...
متن کاملAssessment of ATC Using Voltage and Transient Stability, Simultaneously
Methods for calculating Available Transfer Capability (ATC) of the transmission systems may be grouped under Static and Dynamic methods. This paper presents a fast dynamic method for ATC calculations, which considers both Transient Stability Limits and Voltage Stability Limits as terminating criteria. A variation of Energy Function Method is used to determine the transient stability limit and t...
متن کاملAssessment of ATC Using Voltage and Transient Stability, Simultaneously
Methods for calculating Available Transfer Capability (ATC) of the transmission systems may be grouped under Static and Dynamic methods. This paper presents a fast dynamic method for ATC calculations, which considers both Transient Stability Limits and Voltage Stability Limits as terminating criteria. A variation of Energy Function Method is used to determine the transient stability limit and t...
متن کاملPower System Transient Stability Analysis Based on the Development and Evaluation Methods
A novel method to compute the stability region in power system transient stability analysis is presented. This method is based on the set analysis. The key to this method is to construct the Hamilton-Jacobi-Isaacs (HJI) partial differential equation (PDE) of a nonlinear system, using which we can compute the backward reachable set by applying the level set methods. The backward reachable set of...
متن کاملTransient Stability Assessment Using Individual Machine Equal Area Criterion Part I: Unity Principle
Analyzing system trajectory from the perspective of individual machines provides a distinctive angle to analyze the transient stability of power systems. This two-paper series propose a direct-time-domain method that is based on the individualmachine equal area criterion. In the first paper, by examining the mapping between the trajectory and power-vs-angle curve of an individual machine, the s...
متن کامل