Excess Heat and Unexpected Elements from Electrolysis of Heavy Water with Titanium Cathodes

نویسندگان

  • R. Kopecek
  • J. Dash
چکیده

Excess heat was produced at the rate of about 1.2 watts during electrolysis of heavy water with a titanium cathode weighing 0.0625 g. Analysis of the electrodes before and after electrolysis with a scanning electron microscope (SEM) and an energy dispersive spectrometer (EDS) revealed that new surface topographical features with concentrations of unexpected elements (S, K, Ca, V, Cr, Fe, Ni, and Zn ) formed during electrolysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Excess Heat and Unexpected Elements from Aqueous Electrolysis with Titanium and Palladium Cathodes

Presented here are results of research performed at Portland State University during the period 1994 to 1996. Excess heat was produced at the rate of about 1.2 watts during electrolysis of heavy water with a titanium cathode weighing 0.0625g. Analysis of the electrodes before and after electrolysis with a scanning electron microscopy (SEM) and an energy dispersive spectrometer (EDS) revealed th...

متن کامل

EXCESS HEAT REPRODUCIBILITY AND EVIDENCE OF ANOMALOUS ELEMENTS AFTER ELECTROLYSIS IN Pd|D2O+H2SO4 ELECTROLYTIC CELLS

Electrolyte temperature is a key factor in excess heat production using Pd|D2O+H2SO4 electrolytic cells. Best results are obtained when the electrolyte temperature is close to the boiling point. Stable excess heat is generated by events on or near the Pd cathode surface. In addition to the stable excess heat, heat bursts are sometimes observed. These occurred most frequently in experiments usin...

متن کامل

Electrochemical Calorimetric Studies of the Cold Fusion Effect

Several types of calorimetric cell designs were used in attempts to measure excess enthalpy during the electrolysis of LiOD/D2O using palladium cathodes. Control experiments were run by using light water in place of D2O or by using platinum cathodes in place of palladium. Initial experiments using thin palladium cathodes of an unknown purity gave no significant differences between the Pd/D2O ce...

متن کامل

HEAT MEASUREMENT DURING LIGHT WATER ELECTROLYSIS USING Pd/Ni ROD CATHODES

The heat balance under electrolysis in 1M Li2SO4 light water solutions was measured using Pd rods or Pd coated Ni (Pd/Ni) rods for cathode. We detected large excess heat of more than 10% in 6 of 28 experiments. However, in many other experiments, no excess or only small excess heat was observed. In most cases the excess heat was 5% or less. In order to confirm the excess heat, we have to find t...

متن کامل

CALORIMETRIC MEASUREMENTS DURING Pd-Ni THIN FILM– CATHODES ELECTROLYSIS IN Li2SO4/H2O SOLUTION

A sensitive open-type calorimeter was used to measure excess heat production during electrolysis in Li2SO4/H2O solution with Pt-anode and Pd-Ni thin film cathodes 9000 Å thick, sputtered on Al2O3 substrate. In order to estimate the actual performance and possible measurement errors during electrolysis in the calorimeter used, including heat convection, bubbling and possible H2+O2 recombination,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1996